A 130 MHz LVDS oscillator specifies ±25 ppm pull. What control interface does the board need?

A board uses a DAC voltage to trim its 130 MHz LVDS clock. Purchasing finds a SiT3521 with the same advertised frequency, output format and ±25 ppm pull range. Can it go back on the same control wire? There are two checks: how far the clock can move, and how the board commands the move. The original analog VCXO accepts a control voltage. The specified SiT3521 configuration expects a digital command. Even with the same nominal frequency and pull grade, the board must deliver the correct type of command to the correct pins.

Read the ordering configuration alongside the schematic

SiTime lists the SiT3521AC-2CF2510M130.000000 at 130 MHz and 2.5 V, with LVDS output, a 5.0 × 3.2 mm package, ±10 ppm stability, ±25 ppm pull range and a −20 to +70 °C operating range. It is a digitally controlled oscillator, or DCO. The specific part page also identifies pin 1 as output enable and pin 2 as NC. A quote marked “adjustable” should be backed by the full part number, control interface and logic levels, enable option and packaging. A board with only an analog trim line needs either a compatible analog oscillator or a board and firmware change. The old DAC signal should not be wired to the enable or NC pin.

On the schematic, confirm which serial interface the design uses and how it is wired. Check the I/O voltage, I²C address or SPI chip select, and the applicable pin option. The LVDS pair carries the resulting clock. The digital control pins have a different role. Termination and receiver compatibility remain separate electrical checks. If the board needs a valid clock before the host begins communicating, establish the ordered configuration's power-up frequency and enable behavior.

Programmed pull and guaranteed pull answer different questions

At 130 MHz, 1 ppm equals 130 Hz. The ±25 ppm programmable pull range corresponds to 3,250 Hz on either side, and ±10 ppm stability corresponds to 1,300 Hz. SiTime defines absolute pull range, or APR, as the controllable range remaining after the stated stability and aging effects. For the M ordering option with ±25 ppm programmed pull and ±10 ppm stability, Table 23 in revision 1.02 gives an APR of ±10 ppm, or 1,300 Hz per side.

Suppose a design must guarantee tuning ±15 ppm around nominal across its specified conditions. Each side needs 1,950 Hz. The M option's programmable setting appears large enough, but its guaranteed range is 5 ppm short, or 650 Hz per side. A room-temperature sample that reaches the target establishes behavior at that one condition. A production review can evaluate a wider pull option, a tighter stability grade or a calibration strategy. Identify the life and temperature assumptions that apply to the manufacturer's APR figure. A matching pull figure from another vendor does not establish a matching guarantee.

Turn a +650 Hz request into a control word

At 130 MHz, a +650 Hz request represents +5 ppm. With a ±25 ppm pull range, calculate 5/25 × (2²⁵−1) and round to 6,710,886. The 26-bit control word is 0x0666666. Its lower 16 bits are 0x6666 and its upper 10 bits are 0x066. A −650 Hz request produces −6,710,886, encoded as 0x399999A in 26-bit two's complement. The lower and upper fields are 0x999A and 0x399. These figures represent the frequency fields. Assemble complete register values and serial transactions as specified for the device configuration.

The manual writes the low word before the high word, which initiates the update. For a software-controlled enable option, preserve the specified OE bit in the high-word register when required. If communication succeeds without a frequency change, read back both fields, confirm the configured pull range and inspect the write order. If the output disappears, capture the enable state and supply with the clock waveform.

Measure the untrimmed output before issuing +5 ppm, zero and −5 ppm commands. In a hypothetical example, a part begins at 130,000,520 Hz. After an ideal +650 Hz step it reads 130,001,170 Hz. The change from baseline is +650 Hz, while the final offset from nominal is +9 ppm. Record both. The granularity of the control word is distinct from the accuracy of the frequency counter and the resolution available at the selected measurement interval.

Check timing from the bus write to a usable clock

Figure 29 and Table 24 of data sheet revision 1.02 separate the delay before the output begins to move from the subsequent settling time. Their listed maxima are 140 µs and 20 µs. A single-step timing budget can reserve 160 µs from the end of the high-word write, with controller scheduling and transfer time budgeted separately. For a 650 Hz step, the figure's ±0.5% settling band represents ±3.25 Hz around the requested offset, using the step magnitude as the reference. The maximum command update rate is a separate specification. It does not establish that the clock settles fully between every pair of commands at that rate.

For approval, record the complete part number, guaranteed APR, voltage, temperature range, OE mode and bus wiring together. On the board, capture a full power cycle, steps in both directions, and how the system behaves after communication is interrupted and restored. Test a controller-only restart separately if the oscillator stays powered. Engineering can then judge whether the loop reaches the required frequency in time, and purchasing can tie that conclusion to the correct ordering configuration.