Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

A 100 MHz active oscillator meets the differential swing. Why check common mode too?

A quote for a 100 MHz active oscillator promises approximately 0.8 V of differential peak-to-peak swing. The actual DC levels on the two conductors can still be outside the receiver range. The SiTime SiT9356 offers FlexSwing output settings and distinguishes levels referenced to the supply from levels referenced to ground. Start with the receiver's limits and check the installed termination. Quotes that only say low jitter, differential and 100 MHz do not establish interchangeability.

Calculate single-ended and differential quantities together

Take a hypothetical complementary pair. Each leg has a low level of 0.98 V and a high level of 1.40 V. In the stable complementary states, the difference varies from −0.42 to +0.42 V, or 0.84 V differential peak to peak. The simultaneous mean of the two legs is 1.19 V. Shift the entire pair up by 0.35 V while keeping the same single-ended swing. The differential swing stays the same while common mode rises to 1.54 V. If a receiver allows up to 1.40 V common mode, the second example fails before counting tolerance. Use the receiver and oscillator documentation for actual conditions.

A supplier's differential voltage can mean the magnitude of a single state or the full peak-to-peak difference. Ask for high and low levels on each leg and the load for the measurement. Verify definitions against a waveform or formal table. The SiTime electrical tables give nominal high and low FlexSwing levels, differential peak-to-peak swing and tolerances. Two-character codes select allowed combinations. Ask whether the requested output references supply or ground. Check how the vendor's test termination corresponds to the intended circuit.

Supply-referenced levels move with the actual rail

When both nominal levels are expressed as supply voltage minus a fixed offset, a simple first estimate makes the output's center move with the rail. Suppose its center is 1.20 V at 3.3 V. With a ±10% rail, the supply alone can move by 0.33 V. Under the ideal relationship, the center can range from about 0.87 to 1.53 V while the nominal differential difference stays constant. Actual limits must account for output tolerance, termination and the board. If a receiver needs 1.0 to 1.4 V common mode, passing at nominal supply cannot approve the direct connection. Consider a ground-referenced option or AC coupling and qualify the implemented circuit.

When AC-coupling the 100 MHz oscillator, ensure the receiver has appropriate bias. SiTime gives different arrangements depending on whether the receiver has internal bias and lists conditions on swing and supply options. Before removing the previous bias network or shunt termination, verify that the receiver's internal circuit exists and is enabled for the board. A valid waveform before coupling does not establish the receiver-side common mode. Capture both sides on the same timebase and record single-ended levels, the differential waveform and the receiving network. Those measurements can distinguish an output grade change from a missing bias.

The receiver may have internal termination enabled. Suppose a 100 Ω differential line sees an extra 100 Ω external termination in parallel with an internal 100 Ω resistor. This simplified resistive load becomes 50 Ω. Its load reflection coefficient relative to a 100 Ω line is −1/3. The observed voltage still depends on driver impedance, routing and frequency, so the calculation does not imply that the swing is halved. A higher-swing quotation is not a correction for an unintended extra termination. Check which termination belongs on the production assembly first.

Release the full output configuration

The period at 100 MHz is 10 ns. Capture both legs at the same time and derive difference and mean. Channel skew can appear as false common-mode motion at a fast edge, so check probe offset, deskew and loading. Distinguish settled voltage from overshoot and the receiver's decoding or lock status. Note bandwidth differences from the data sheet and avoid treating a dynamic peak as the specified steady level. After a room-temperature check, test rail and temperature limits. If the two devices use separate supplies, check startup order as well.

Review swing and common mode as separate limit bands. If an order lists only typical values, request worst-case levels over supply and temperature. Use a captured waveform at a different frequency or termination for sample screening only. The worst common mode, swing and overshoot may occur at different corners. Do not extrapolate a single measurement at one rail and room temperature. Document which condition fails first before changing the supply, tolerance or bias or rejecting the alternate.

Once the output code, supply option and termination are chosen, freeze them on the purchase order with frequency, package, stability and enable behavior. Hold a same-frequency, same-package offer for output mapping and supply confirmation. Qualify both differential swing and common mode at the receiver before release. When replacing the existing 100 MHz active oscillator with another signal format, qualify the schematic and termination changes with the part. A counter only confirms the frequency. Preserve the complete part and test conditions so another buyer can reconstruct which difference governed first-article approval.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.