Two differential oscillator sample reports quote −75 dBc and −93 dBc. Both are typical figures for the SiT9375 FlexSwing ER output option. They describe power-supply-induced phase noise with 50 mV peak-to-peak ripple on VDD, with the latter measured using the RC supply filter in Figure 9. The unit dBc describes a discrete component relative to the carrier. Random phase-noise density expressed in dBc/Hz is a different measurement.
Verify the full output option, then build the supply and differential termination from the manual. Identify the ripple injection and observation points. A generator set to 50 mV does not guarantee 50 mV peak to peak at the intended node. In filtered and unfiltered setups, note where ripple was measured and its value. Ripple measured before the filter is not the ripple at the oscillator supply pin.
Record a baseline with ripple disabled. Inject a single-tone ripple and record the resulting lines on both sides of the carrier. Changing the ripple frequency and checking whether the lines move helps distinguish injected response from fixed interference. Keep analyzer bandwidth, termination, and carrier frequency the same. If a line approaches the noise floor, report the upper bound that can still be resolved.
State that the data are typical for ER and record the filter topology and measured ripple alongside the spur level. If purchasing needs a guaranteed limit for every unit, agree on offsets and limits separately. This keeps the contribution of the board filter distinct from oscillator performance.SiTime SiT9375 datasheet, FlexSwing ER parameters and Figure 9