Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Does a SiTime SiT3521 156.25 MHz differential oscillator need a command before it outputs?

A board in a network switch uses a 156.25 MHz differential oscillator as a receiver reference. A prototype responds over the SiTime SiT3521 serial interface but has no clock at cold startup. Another sample starts driving the output after power is applied. An otherwise matching family, supply, temperature, and frequency can have a different output-enable ordering option. Software control requires a register write, whereas hardware control uses a pin. Ask for the reset sequence and the first clock consumer's deadline before accepting a substitute. Configuring the intended frequency verifies only one part of correct behavior.

Decide what can start the reference clock

The ordering information lists three OE arrangements. Software control leaves pins 1 and 2 unconnected. With hardware control, one of those pins is OE and the other is unconnected. Check the actual code and package drawing. A hardware OE input has an internal pullup. A valid high enables output and a low puts both output pins in high impedance. Software OE defaults to disabled at power-on and requires a control write over I²C or SPI. Use an independently clocked controller or other valid board sequence to issue that command. If the processor issuing it needs the target reference before it starts, hardware and software can end up waiting for each other.

For hardware control, establish that the board net goes to the approved OE pin. A pin-2 version on a board wired for pin 1 can route the external signal to an unconnected pad. The actual enable state then depends on the internal pullup. A bench sample may output normally while failing to stop the clock during reset. If the customer instead needs the reference delayed until firmware issues a command, review whether a hardware part with OE high would feed the receiver too early. Identify the actual enable pin or software mode, firmware availability, and required startup on separate quote lines. Receiving can check the suffix and repair can identify the configuration without guessing from a wave trace.

Time the event that starts each limit

The manufacturer specifies up to 3.0 ms startup from the supply reaching its rated minimum. Hardware enable or disable takes up to 3.8 µs after the input reaches its specified logic threshold. Software enable or disable takes up to 6.5 µs after transmission of the last byte of the command. Assign the correct event to each limit. Suppose the enable command ends 18.0000 ms after power crosses the minimum, with valid startup, command, and termination. The 156.25 MHz differential oscillator can then take until 18.0065 ms to reach the specified swing. If the receiver needs a clock at 10 ms, that implies about 8.0065 ms of shortfall in the illustrated budget. The command-to-output delay alone cannot establish that the deadline is met.

Use the same event definitions for the acquisition. Set time zero at the measured supply crossing. Place a marker on the hardware threshold or the final bus byte. Mark when the differential output reaches the specified swing. Also record when the receiver leaves reset and can use the clock. A serial acknowledgment can coexist with a disabled output if the relevant field was not written. Align the pin voltage, bus frame, termination, and scope traces to distinguish scheduling, interface, and device behavior. When the supplier sends only a steady-state waveform, ask for evidence at these startup points as well.

Avoid carrying the previous state into a cold restart. A fixture that resets only the controller without bringing the oscillator rail through a controlled power-off can leave an already enabled output running. Test the controller-only reset and then a full cold startup with device-pin voltage recorded. Archive the traces separately. This matters when a serviced unit normally uses software reset and fails only after the whole assembly loses power.

Exercise firmware tuning on first article

The software OE bit shares a register word with upper bits of the digital correction word. Once the software-controlled part runs, make an allowed frequency adjustment and verify that the OE bit retains its intended value. A maintenance routine that overwrites the word can clear the enable bit. During substitution, use the same validation board to record cold startup, initial enable, tuning, and disable. This catches a later dropout that a spot frequency reading would miss. For hardware OE, the register description says that software OE writes have no effect. Verify the physical control instead. Both variants can pass a frequency check, but stop and resume testing must use the ordered control scheme.

Put the complete code, 156.25 MHz startup frequency, differential standard, supply, and enable selection on the request. Associate the board with the correct startup software and test revision. A configurable sample without a confirmed order code can stay in engineering. When material arrives, retest with the approved procedure. For software-controlled samples, verify the disabled state before the fixture issues its command as well as the enabled state afterward. If a lot specified for hardware control does not stop after pulling OE low, establish the actual pin, pad waveform, and full code before escalating. Retain the deadline, measurements, and receiver state so repairs can reproduce the release conditions.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.