Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

What vibration band applies to the 0.1 ppb/g limit on a SiTime 156.25 MHz differential oscillator?

Industrial test equipment uses a 156.25 MHz differential oscillator near a motor. Purchasing finds a 0.1 ppb/g acceleration-sensitivity figure in the SiTime SiT9346 data sheet and proposes it as a comparison limit. Engineering needs the in-service change of frequency under vibration. The manufacturer limit comes with an ordering grade, a three-axis definition, and a vibration-frequency range. Specify the measured mechanical environment, timing interface, and allowable change before comparing alternatives. Keep the device specification, board acceleration, and communication behavior in the same review.

Use the ordering field and electrical table to establish the scope

The SiT9346 is a MEMS differential oscillator. The ordering table uses A in the special-features field for low acceleration sensitivity. The common electrical table gives 0.1 ppb/g maximum for that grade, with a three-axis gamma vector, a vibration band of 15 Hz to 2 kHz, and the stated calculation method. Receiving needs the full code containing the applicable field. The letter A can also appear in the silicon revision. Read the code position against the manufacturer diagram. Keep output format, supply, package, stability, enable option, and feature selection together so the board termination and test can be traced to the exact configuration.

The table includes two different kinds of frequency. The clock output is 156.25 MHz. The 15 Hz to 2 kHz range describes mechanical excitation. For example, a measured 300 Hz motor component is inside the stated band, while another motion at 10 Hz is below it. The stated limit cannot establish behavior at 10 Hz. Request additional evidence from the manufacturer or test the board under the actual conditions. Measure acceleration near the oscillator rather than converting a motor nameplate into an assumed component spectrum.

Convert the coefficient into a value the application can assess

Take a simplified single-tone estimate. Suppose measured sinusoidal acceleration at the part is 5 g peak at 300 Hz in one direction. Multiplying 0.1 ppb/g by five gives 0.5 ppb. Multiply by 156,250,000 Hz and divide by one billion to get about 0.078 Hz of frequency-deviation amplitude. This uses the three-axis bound conservatively for one direction and assumes the condition follows the linear sensitivity model. It estimates the scale of one disturbance. For random or multifrequency vibration, peak, RMS, and phase relationships across axes affect the result. An acceleration RMS value does not directly produce a peak frequency deviation. Specify the spectrum, axes, and statistic for a random-vibration requirement.

Keep this amplitude separate from equipment timing error. Vibration-induced frequency shift changes with the motion, with sign and magnitude affected by orientation. Label the measurement duration, frequency reference, and equipment settings even when a test provides a single maximum frequency deviation. A phase-jitter requirement needs a vibration-on phase measurement with the specified integration limits. The calculated 0.078 Hz alone does not give a fixed picosecond value. A fixture may resonate, making local board acceleration exceed the shaker's displayed value. Retain the fixture, mounting position, and sensor direction before interpreting frequency response.

A counter that reports once a second may average many cycles of a 300 Hz sinusoidal disturbance and show little movement. Specify whether acceptance uses mean frequency, instantaneous deviation amplitude, or phase within an operating band. Before measuring modulation amplitude, verify on a known signal that the measurement chain detects variations at the target frequency. If the report contains only one-second averages, ask how the instrument computes them. A flat average trace cannot establish immunity to vibration.

For a comparison, use consistent sensor positions and orientations and record the order of axes. If one board has a different brace, avoid assigning the entire assembly difference to the component’s acceleration sensitivity. Check how both samples were mounted and decide whether to repeat under common conditions or qualify the specific board-and-mount assembly.

Check the code at receiving and the installed behavior in qualification

Link each 156.25 MHz differential oscillator specimen to its full code, supply, load, and fixture. Start with basic frequency and waveform on the bench. On the actual mounting, compare a baseline to the defined vibration test and record how the board was fixed. Use the same approved termination and supply when comparing compatible variants. A supplier report with only room-temperature jitter can support its electrical check, while vibration evidence needs the agreed conditions. Engineering should state whether startup, continuous output, or link behavior must pass during vibration. The parties can then apply the same test to the same requirement.

A stiffer bracket may reduce acceleration at the oscillator even though nominal frequency and load are unchanged. Tie component qualification to the applicable board and record the mounting revision used for qualification. If a supplier provides data under a different frequency band or direction, retain the discrepancy for review. Material that passes identity and room-temperature checks can remain controlled for engineering while the project completes vibration verification. Once the exact configuration and board evidence match, issue the lot for the corresponding assembly.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.