A spread-spectrum clock distributes energy over a frequency band, so a narrowband peak can fall without an equal reduction in total energy. A lower fundamental on an oscilloscope or spectrum analyzer does not establish a system emissions improvement by the same number. Receiver bandwidth, detection, harmonics and actual radiation paths also matter.
Turn spreading on and off under fixed measurement conditions
Use the same board, workload, probe or antenna location and cables. Hold receiver resolution bandwidth, detector, dwell and scan span fixed. Record the fundamental and harmonics of interest without spreading, then enable it. Cover the complete spread envelope rather than marking only the former peak. If the bandwidth captures more of the distributed components together, the change in displayed peak will differ from a narrower measurement.
For the same fractional deviation about the center frequency, the third harmonic can span about three times as many hertz as the fundamental. Actual radiation in each band still depends on the board, harness and enclosure. A neighboring peak can become the worst one after another falls. Find peaks again and record the smallest margin to the limit.
Ask for the full order code, spread depth and modulation waveform. Keep comparable system traces with spreading on and off. For a formal test, use the required receiver settings and arrangement. A conducted trace at one board point cannot replace it. A lower peak at one angle and polarization may leave another as the limiting condition. Include the orientation that produced the worst peak in earlier verification.SiTime AN10005 spread-spectrum oscillators and EMI measurement guidance