A board uses SY89832U to distribute differential clocks to four receivers in the high-end version and two in the reduced version. Purchasing proposes deleting the two modules and their terminations together. The manufacturer requires a 100 Ω resistor across each unused differential Q0–Q3 output pair. Removing the receiver does not automatically allow its output pair to float. Locate the termination on the baseboard or removable module.
Track the termination for each assembly option
For each output pair, mark the driver, connector, and across-pair resistor on both assembly drawings. A termination inside a receiver disappears when the plug-in module is removed. Provide the required termination for the empty position. If the low-end configuration adds a replacement resistor, do not leave both 100 Ω terminations in place when the receiver is fitted. Two ideal 100 Ω resistors in parallel give about 50 Ω.
Inspect what is fitted as well as the schematic
Check the fitted designators, then inspect amplitude, eye pattern, or timing on used channels under specified conditions. Powered measurements and unpowered resistance measurements have different limitations, and internal parallel paths can affect readings. A plausible reading alone does not prove the designated resistor is fitted. Retain a baseboard photo with the receiver module removed.
Purchasing can keep separate resistor lists for each assembly option. On the next reduced-output order, this shows which designators can be removed and preserves the requirements on unused pairs. Microchip SY89832U output pin descriptions