A precision counter board uses a Taitien NI-10M-3500 series 10 MHz oven-controlled crystal oscillator. Its designer wants pin 2 to provide a reference to both a calibration circuit and a voltage monitor. First confirm what the pin does on the ordered part, then calculate the combined load. Taitien lists reference voltage, oven monitor or no internal connection for pin 2. The reference-voltage option also specifies minimum load impedance. A unit with the right frequency, supply and outline can still have a different pin function. A working 10 MHz signal cannot release a part with the wrong auxiliary pin.
Specify pin 2 on the purchase record
Taitien lists pin 1 as a tuning input or internally unconnected. Pin 2 can provide reference voltage, oven monitoring or no connection, depending on the specification. The manufacturer states that a pin without specified parameters is internally unconnected. Pin 3 supplies power, pin 4 provides clock output and pin 5 connects ground and case. Request the full ordering code, drawing view and functions of the pins actually used. Confirm temperature and aging against the ordering table. A family suffix alone cannot establish which auxiliary options can be combined.
For the reference-voltage option, the table gives 2.8 V typical, 2.716 to 2.884 V, a 9 kΩ minimum load resistance and a temperature stability figure. Keep voltage, load and temperature together on the approved specification. An open-circuit result near 2.8 V shows that the pin responds. Verify reference behavior under the approved board load before release. When another 10 MHz OCXO has the same outline and a pin in the same position, establish whether it is a reference, a monitor or unconnected before powering the board on that assumption.
Combine parallel loads before comparing them with the limit
Assume the reference drives two 20 kΩ resistive inputs. Each meets 9 kΩ by itself, but their parallel equivalent is 10 kΩ. Add a third 50 kΩ direct DC path to the same reference and the total drops to about 8.33 kΩ, below the data-sheet limit. At an ideal 2.8 V this draws about 0.336 mA, compared with about 0.311 mA across 9 kΩ. The current calculation illustrates the margin without predicting a specific voltage outside the manufacturer's conditions.
Even with two 22 kΩ inputs, the equivalent including the third branch is only about 9.02 kΩ nominal. If the first two resistors each reach 1% below nominal while the third remains 50 kΩ, the equivalent falls to about 8.94 kΩ. Three individual nominal values do not establish a worst-case load. If a branch is buffered, use the buffer input under actual operating conditions instead of treating unrelated circuitry as a resistor to ground. A sampled input can also draw transient current. Capture the reference during enable, disable and switching events as well as in steady operation.
Verify reference voltage separately from the 10 MHz output
The CMOS clock output has its own levels and load conditions. Do not use the reference as a low-impedance supply or use clock activity as proof that the reference passes. Capture tuning voltage, reference output and measured frequency on the assembled board, recording instrument and probe impedance for each. First verify the reference in a permitted test load, then connect the production controller and exercise monitoring, buffering and power cycling. If removing an instrument changes the result, record that observation because the measurement can add load.
For a tunable pin 1 option, the data sheet lists 0 to 2.8 V, a 1.4 V center and positive slope. Measure the voltage actually applied and identify its source. Verify whether the reference feeds a divider, a converter or a high-impedance sample input. Do not infer internal connections from the presence of an auxiliary reference. Reference accuracy, tuning range and frequency budget each need review against the real circuit and exact guarantee. Initial accuracy is also tied to temperature, elapsed time after power-up, date code and tuning voltage. Apply those conditions so drift in the reference network is not assigned to the oscillator itself.
Use the ordering table to check the combination during appraisal. For example, the wide-temperature NI-10M-3500 and NI-10M-3501 share the ±0.1 ppb temperature row but list ±10 and ±20 ppb yearly aging respectively. At 10 MHz those are ±0.1 and ±0.2 Hz for that budget item. Confirm the interval and conditions for the project. This calculation does not qualify reference loading, and the aging column does not identify pin 2. Confirm both with the supplier.
The purchase order can identify the temperature and aging grade, clock output and both optional pin functions on the 10 MHz OCXO. Keep a family-only quote under review until the supplier confirms the options and reference load. On first articles, capture the auxiliary signals and active clock with the actual parallel branches attached. If the worst-case load falls below 9 kΩ, revise the interface or obtain an applicable guarantee and repeat qualification. Preserve the exact code and measurement points so the next option or supplier change has a clear release decision.