Does a Taitien OB-U 156.25 MHz differential oscillator pass if its peak-to-peak voltage is in range?

A switch board has a replacement reference clock. A technician measures 630 mV differential peak to peak and compares it with the existing swing limit. For Taitien's LVDS OB-U, the manufacturer also limits the mismatch between the two differential output states. When buying this 156.25 MHz differential oscillator, first confirm LVDS on the order. Then capture both plateaus. A passing peak-to-peak number alone does not establish state balance.

Keep four plateau measurements in the lab report

The LVDS table in Taitien XO-0200 specifies 100 Ω across the outputs. It lists VOD from 247 to 454 mV, with a maximum 50 mV difference between the magnitudes in the two states. It separately lists VSW from 0.494 to 0.9 V. Measure the stable signed differential voltage in each state, take the magnitudes and find the difference. The sheet also gives a 1.125 to 1.375 V common-mode range and a maximum 50 mV difference between the two states. Request both differential plateaus, both common-mode plateaus and the original capture in one report.

Suppose the stable differential levels are +345 mV and −285 mV. Their span is 630 mV and both magnitudes lie within the VOD limits. They differ by 60 mV, exceeding the mismatch limit by 10 mV. If the common-mode values are 1.21 V and 1.28 V, each falls within the per-state range but the difference is 70 mV. A report recording only the total swing and mean common mode can miss both failures. These illustrative values define the acceptance decision and are not measurements of an OB-U sample.

Identify the measurement plane

Start with the specified differential load and supply at the device, then measure at the receiving IC. Connectors, coupling capacitors and added bias can change common mode and symmetry. If source measurements are unequal, swap equivalent measurement channels while keeping the branch connections unchanged. Check whether the difference follows the channel. A common signal can verify gain and deskew. Document bandwidth, input coupling and reference. An absolute common-mode measurement needs DC information and a probe arrangement that does not change the 100 Ω load. A mathematical subtraction can show the differential signal even when AC coupling has removed the original DC operating point.

At 100 Ω, the nominal 330 mV differential magnitude corresponds to about 3.3 mA through the termination. That estimate is the voltage divided by termination resistance. It does not describe supply current or other bias loads. Measure the actual termination value and identify its position before comparing the inferred current against a setup. HCSL and LVPECL options have their own ratings and termination requirements. Apply the four LVDS acceptance items only to the configuration they cover.

Calculate common mode from both conductors at the same instant. With the positive and complementary pins at 1.42 V and 1.08 V, their difference is +0.34 V and their mean is 1.25 V. At 1.02 V and 1.33 V, the difference is −0.31 V and common mode is 1.175 V. The magnitude difference is 30 mV but the common-mode difference is 75 mV. Averaging one channel's extrema can miss that failure. Keep both original channels so the lab can repeat the calculation.

Account for measurement uncertainty in the decision. A measured 48 mV state difference with 5 mV uncertainty is a boundary result under an appropriate agreed rule. Check both channels against a stable symmetric signal before using the approved oscillator load and supply. In an assembled board, record the bias network's power state and measurement points. Tell the supplier whether the issue is total swing, differential balance or common-mode change so their lab can test the same parameter.

Attach the state limits to the actual order

OB-U lists 156.25 MHz as a designed standard frequency. The note says this does not establish stock, and the sheet indicates that some options cannot be combined. Ask for the complete number, LVDS output, supply, temperature grade and package. Keep the manufacturer termination and state limits in the component approval. Record the system receiver window separately. If asymmetry appears after assembly, compare the measurement planes before deciding whether receiving should isolate the lot or engineering should investigate the channel.

Identify which conductor is positive in the first-article capture, and mark the two plateau measurement windows. A window on the switching edge includes time skew and will not measure a stable state. Record whether the receiver supplies termination so a fixture does not accidentally add another 100 Ω. The recorded sample identity, load and measurement timing make the same limits usable on the next purchase.