The customer requires spurs below −80 dBc on a 100 MHz sine-output OCXO, but receiving inspection sees a higher line at the second harmonic. Taitien's NJ-100M-6800 specifies harmonics and spurs separately: −30 dBc for harmonics and −80 dBc for spurs from 10 Hz to 1 MHz from the carrier. The 200 MHz second harmonic and discrete spurs close to the 100 MHz carrier have different limits and scan windows.
Separate harmonic and close-in spur requirements in the RFQ
Ask whether system engineering limits integer harmonics, close-in interference or both. List the fundamental, harmonic orders to check, offset span on either side of the carrier, and limits. dBc is power relative to the carrier. Retain the carrier reference in the same acquisition settings. If the contract also limits absolute spur power, add a dBm field and convert using measured carrier power.
Check that the instrument is not generating the harmonic
Measure the fundamental into the specified load. For harmonics, check analyzer frontend headroom by varying input attenuation and observing the line relative to the carrier. For close-in spurs, use an appropriate span and resolution bandwidth, and save the original plot showing proximity to the noise floor. A single peak value without axes or resolution settings is hard to reproduce.
If the customer also requires the second harmonic below −80 dBc, obtain evidence for that separate limit or have engineering evaluate downstream filtering. Use the relevant spectrum masks to compare the total cost of alternatives. Taitien NJ-100M-6800 output specifications