A standby timing board has a 2520 footprint and uses Taitien's OY-I. A supplier proposes OY-D for longer backup battery life. Both are 32.768 kHz active oscillators with a nominal 2.5 × 2.0 mm outline. They differ in current consumption and pin 1 function. Establish whether timekeeping must continue after main power goes away and whether the old board drives pin 1. Accepting on package, frequency and family name alone can leave the replacement driving a clock during shutdown or the RTC without a source during backup.
Compare no-load and typical specifications
One full OY-D specification lists 1.5 V and 1.8 V options, both with ±5% supply variation. It gives 1.4 µA typical and 1.8 µA maximum no-load current. The OY-I sheet lists 1.8, 2.5 and 3.3 V options, up to 35 µA no load, and a separate controlled standby-current figure. A family summary may highlight a typical result or a different option. Request the exact suffix, guaranteed conditions and current document. When the clock must keep running without main power, budget running current and additional load. OY-I standby current does not represent continuous timekeeping.
For a 90-day estimate, assume a valid rail throughout and the no-load maxima above. Exclude battery leakage, the regulator and the receiver. Ninety days is 2,160 hours, giving approximately 3.888 mAh for OY-D and 75.6 mAh for OY-I. These are oscillator-only budgets. A typical result from a supplier for the 35 µA option cannot establish a guaranteed product lifetime with a lower average. Include output capacitive charging, receiver current, any bias or pulls, temperature and battery variation on the actual board.
Check how the first pin behaves on the board
The OY-D sheet calls pin 1 NC. OY-I uses it for three-state control and gives thresholds relative to the supply. The remaining supply, ground and output positions align, but the two parts cannot be assumed to respond to the same sequence on a control pin. For continuous timekeeping, check its state with main power off and ensure the receiver tolerates input when unpowered. If the previous circuit relied on disabling the oscillator output to prevent back-powering, a part with an NC pin needs isolation or sequence review. Follow the pin handling instructions and verify the actual startup state.
Review the backup rail as well. A 1.8 V ±5% option spans 1.71 to 1.89 V. If the backup regulator measures 1.68 V, it is 30 mV below that minimum. A stable frequency observed on a bench does not extend the rating. Repeat main-to-backup switching with the least favorable battery condition and record oscillator supply, receiver, battery voltage and changeover time. If source and receiver use different rails, check logic thresholds and what the unpowered receiver accepts. Use the result to decide whether the quoted alternate can qualify.
A family summary can use different test conditions from a detailed sheet. The cited OY-D document lists 1.4 µA as typical no-load current, an 8 ms startup maximum and frequency entries based on a three-day average. For a restart design, do not use a family example as a guaranteed maximum for every package, voltage and option. Give quality the exact revision and maximum confirmed by the supplier. If the receiver requires uninterrupted clock during transfer, even an 8 ms restart gap can be unacceptable. Measure the actual takeover to distinguish restart from continuity.
Define a first-article test for actual backup timekeeping
If a quote offers a 32.768 kHz passive crystal, identify the receiving oscillator circuit. Its material record differs from a powered source with a CMOS output. For the 32.768 kHz active oscillator, observe main power loss, backup takeover, clock and changes in the RTC registers. Use the approved waveform method and distinguish probe capacitance and leakage from the production load. If the supplier only tested settled operation, add the transition. When the output stops during backup, restarting it later does not replace missed clock counts.
Continuous backup also has separate edge and frequency requirements. If the qualified configuration uses ±25 ppm as its full interval frequency error assumption, 24 hours corresponds to approximately ±2.16 seconds. A tighter system limit still needs a frequency review even if the replacement reduces battery use. Compare elapsed time without main power with a traceable clock. A definite block of missing edges points toward changeover. A continuous edge stream that accumulates a proportional time error calls for checking frequency, temperature and calibration. Keep the evidence distinct to decide whether to change the supply interface or stability grade.
The approval record can include the full code, pin function, measurement conditions for running and standby current, voltage and temperature combination, and verified package drawing. If the product needs to stop the clock in sleep, confirm how the selected oscillator does so and test restarts. If timekeeping must continue in every sleep interval, verify the running current and receiver compatibility. Release after first articles pass under the complete ordering code. Keep low-voltage and backup-transition evidence traceable to the received lot.