A buyer copies a precision TCXO's ±2 ppb per degree temperature slope into an acceptance sheet. A second entry, ±0.02 ppb per second, looks like a change of unit. The two entries serve different purposes in a clock reference. One estimates fractional frequency changes with temperature. The other limits how quickly frequency changes under the stated temperature ramp. A simple conversion assumes the local temperature follows the stated rate and the compensation response introduces no relevant dynamic effect.
In the SiTime SiT5347 Rev 1.02 datasheet, page 4 lists a maximum ±2 ppb/°C and a separate maximum ±0.02 ppb/s for −20 °C through 85 °C, with a 0.5 °C/min ramp. The colder and warmer ranges have separate values. The Stratum 3 grade on page 5 has a different set. Retain the ordering grade, temperature segment, and ramp speed next to each number. A family name alone does not select the applicable row.
Compare the scales at the stated ramp rate
A ramp of 0.5 °C per minute is about 0.00833 °C per second. Multiplying by 2 ppb/°C gives about 0.0167 ppb/s. This is in the same range as the independently specified dynamic limit of 0.02 ppb/s. Use the stated limit and conditions during qualification. At 100 MHz, 0.02 ppb/s is about 0.002 Hz per second. That small change can be difficult to distinguish from instrument resolution during a short observation.
Suppose the clock changes at 0.02 ppb/s in the same direction for 30 seconds. It ends 0.6 ppb away from its initial frequency, or about 0.06 Hz at 100 MHz. If the frequency error starts at zero and grows linearly, the average is 0.3 ppb and the accumulated time error is about 9 ns. A baseline error needs its own budget term. A slew limit alone does not establish absolute frequency error, peak time error, or what an attached synchronization loop can track.
Measure the temperature rate at the equipment
Increasing the chamber setting to 2 °C/min does not establish that the same limit applies. Chamber temperature can differ from the part's immediate environment. Changing fan operation can cool the vicinity of the device quickly while the rest of the enclosure remains nearly unchanged. Log temperature and frequency on the same time axis and record probe position, attachment, and interval. Repeat the manufacturer's condition before comparing it with the equipment condition when feasible.
For discrete frequency records, divide adjacent changes by their actual measurement interval. A short interval magnifies frequency-estimation noise. A long averaging interval can conceal a real transient. Record the differencing interval, instrument reference, and filtering. Retaining the traces lets the engineering team recompute the result when the acceptance window changes.
Save a baseline with the temperature setpoint and test wiring unchanged. That shows the measurement chain’s own apparent slew and helps explain a result close to the limit.
Compare warming and cooling. A different frequency at the same temperature is evidence that a single slope does not describe both directions. For a run crossing several datasheet temperature segments, save maxima for each segment and raw recordings around the boundaries. Mark logging gaps and system lock transitions separately from continuous device frequency behavior.
Give the supplier the conditions the system needs
An inquiry can specify the ordering grade, allowed temperature range, fastest measured ramp in the enclosure, allowable frequency slew, and the kind of documented test expected. A full-temperature ppm figure is still useful for a slow-change error budget. An equipment design that depends on a dynamic limit needs evidence at the relevant ramp and configuration. In the acceptance sheet, give both limits, their test conditions, and the calculation window.