Both TCXOs warm by 8 °C. Why can their holdover errors differ by a factor of three?

Two instruments lose their external timing reference during the same test. Both ultimately warm by 8 °C. The first warms throughout the run. The second stays near its starting temperature until the last part of the run. A report that gives each instrument the same peak temperature rise omits how long its clock spent running with a frequency error. For an instrument that timestamps records, the accumulated time difference during the outage is what matters.

SiTime's holdover paper distinguishes frequency holdover, the deviation from the frequency before the outage, from time holdover, the accumulated time error. AN10063 also discusses the effect of the frequency-versus-temperature slope on dynamic time error. Use those definitions in a budget and check the actual device's definition, test profile, and airflow. A typical slope and a maximum operating temperature alone cannot reproduce a vendor's holdover test.

Put frequency and temperature on one timeline

To isolate the temperature term, assume that over this small range the clock shifts upward 10 ppb per degree from its initial frequency. The test lasts 1,200 seconds. Device A warms linearly from zero to 8 °C above its starting point over the full interval. Its frequency error rises from zero to +80 ppb, for an average of +40 ppb. Multiplying that fraction by 1,200 seconds gives a gain of 48 microseconds. Device B remains at its starting temperature for the first 800 seconds, then warms linearly by 8 °C over the last 400 seconds. Its +40 ppb average applies only during those 400 seconds, and it gains 16 microseconds. The final frequency errors agree even though the accumulated errors differ by a factor of three.

If both units then stay at the warmer temperature for 300 seconds, each gains another 24 microseconds. The respective totals become 72 and 40 microseconds. Mark intervals and multiply each average error by its duration. A triangular or trapezoidal estimate assumes adequate linearity between the temperature and the frequency in the interval. If the slope changes substantially, split the calculation or integrate measured frequency samples.

Set a defensible starting point for the test

Observe the equipment's time output against a common reference before the outage and mark when the reference is actually taken away. An initial 6 microsecond offset belongs in its own column. A correction step upon reference recovery can hide the maximum during the outage. Keep the complete time-difference trace, then extract the final offset, the largest excursion, and the recovery adjustment according to the equipment acceptance rules.

Record temperature near the part as well as in the chamber and, where useful, the chassis airflow. Use a shared timebase for the logs. The board near the part can lag the chamber or warm when a nearby device turns on, even when the chamber stays at its setpoint. Document probe location, logging interval, and assembly state. Change one heat source at a time and see whether the resulting clock changes repeat across units.

With sampled frequency data, check for gaps near the heat-source switch. Identify missing intervals on the timeline rather than treating them as zero error.

The worked calculation leaves out baseline frequency error, random noise, and long-term aging. A positive 20 ppb starting error adds another 24 microseconds over the first 1,200 seconds. Cooling could later contribute an opposite sign and make the final error look small, although the time difference crossed the limit halfway through. An uninterrupted synchronization requirement should be evaluated against the worst relevant instant.

Ask suppliers about the actual temperature profile

An inquiry can state a twenty-minute reference interruption, a possible 8 °C rise measured on the board, and whether the rise can begin as soon as the interruption starts. Include the allowable timing error and the initial lock condition. If the reply only quotes ±0.5 ppm over temperature, ask how it is measured and what profile applies to any dynamic holdover claim. A conservative frequency envelope remains useful until the assembly has been measured. Keep the guaranteed figures, the local-slope calculation, and the assembled equipment measurement separate in the qualification record.