The same wide-temperature-range TCXO reads several hertz apart on two occasions when the temperature near its case is 40 °C. The first reading is during warm-up from cold, the second during cooling after the fan starts. Firmware that uses a temperature correction table would apply the same correction both times. To decide whether the table is adequate, compare the heating and cooling curves at the same temperature.
Read frequency twice at the same temperature
SiTime's glossary defines thermal hysteresis as the maximum frequency difference at the same temperature between the heating and cooling curves. Imagine measuring the vertical separation of the curves at every temperature and taking the largest. Subtracting the lowest frequency on the plot from the highest may compare points tens of degrees apart. That gives the overall frequency span of the sweep. The sweep direction is needed to recover the difference at a matched temperature.SiTime oscillator glossary and thermal hysteresis diagram
Suppose a 26 MHz sample reads 26,000,004.0 Hz during heating and 25,999,998.8 Hz during cooling at 40 °C on the board. The difference is 5.2 Hz, equivalent to 0.20 ppm relative to nominal. If software uses their midpoint as the correction reference, the residuals for this pair are +2.6 Hz and −2.6 Hz. A correction calibrated only on the heating curve can leave a cooling residual of the full 5.2 Hz. This example gives the correction margin at one point. Find the worst residual over the range using the other temperatures too.
The chamber setpoint may differ from the sample temperature
Give timestamp, chamber temperature, board temperature near the oscillator, output frequency and sweep direction separate columns. Keep supply, output load and the main board heat sources consistent, and mark the sensor location on a photo. Pairing readings by chamber air temperature alone can compare a board still cooler than the air during heating with one still warmer during cooling. Some of the apparent curve separation may reflect the difference between the sensor location and the device. A board probe reports its mounting location and does not directly measure the resonator's internal temperature.
Repeat the measurements at the temperatures that disagree. Approach each target from opposite directions, dwell there and keep a continuous record of board temperature and frequency. Take readings using the agreed stabilization rule. If slowing the sweep or extending the dwell reduces the gap, consider sweep rate, thermal lag and board heat sources first. If it persists over multiple cycles, report each difference and their range. If the equipment actually sees a sudden fan start or rapid heating, keep separate traces at those real rates to show the error it experiences in service.
What to put in the selection record
Ask the supplier for the complete order code, specified temperature range, reference frequency used for stability, heating and cooling conditions, and whether the stability limit includes hysteresis. A typical curve can guide the choice of retest temperatures. Set separate limits and conditions for production acceptance. When comparing two devices, use the same vertical-axis units and reference so automatic scaling does not make unequal deviations look alike.
A report can state the temperature of the largest difference between heating and cooling over the measured range and the temperature of the largest one-sided residual after correction. Attach the raw readings in both directions, timebase and sampling interval. If maintenance changes fan control or moves the temperature sensor, retest the relevant portion of the range to see whether the table still applies.