If a 19.2 MHz TCXO shows a suspiciously small waveform when connected to an instrument set to 50 Ω, save the wiring diagram and instrument settings first. That number describes the load the instrument presents to the oscillator. Two instruments can both read 19.2 MHz while presenting loads that differ by orders of magnitude.
Set up the test using the datasheet for the exact configuration
The Epson TG2016SMN 19.200000 MHz CCGNEM configuration has a clipped-sine output and a nominal load of 10 kΩ and 10 pF. It requires an external DC-blocking capacitor, with 0.01 µF as the specified minimum. A direct 50 Ω coaxial termination presents only one two-hundredth of the nominal resistance. The resulting amplitude cannot be compared directly with the specified limits or used to infer the oscillator's drive capability.Epson datasheet for this configuration, Section 2 operating conditions
A high-impedance probe is only the first step. Probe input capacitance, pads and traces all contribute. If the probe alone is close to 10 pF, adding another 10 pF exceeds the target. Check the DC-blocking location in the datasheet circuit, then estimate the combined fixture and probe load. If you cannot reproduce the circuit, label the result as a measurement at this board's receiver and record the probe point, supply and coupling.
The nominal supply for this configuration is 3.3 V. For a 1.8 V design, obtain the datasheet for the corresponding configuration even if its part number also begins with TG2016SMN. Keep the order code and test conditions with the waveform so the next board or probe can be compared.