Two proposals for a CC2652R board give the same frequency and 50 Ω maximum resistance, with nominal loads of 7 pF and 8 pF. Procurement wants to use one qualification. The TI high-frequency oscillator table specifies a load-dependent motional inductance in addition to frequency, load and equivalent series resistance. When buying a 48 MHz passive crystal for this device, ask the crystal manufacturer to confirm the motional-inductance limit and the full part to which it applies. Both candidates can pass the resistance row while only one has evidence for the other condition.
Read the resistance bands and the board load together
The CC2652R data sheet lists measurements on TI's reference design. For a load greater than 6 pF through 9 pF, the resistance maximum is 60 Ω, with 20 Ω typical. For greater than 5 pF through 6 pF, the maximum is 80 Ω. Keep the exact endpoints. The 7 pF and 8 pF proposals both fall in the 60 Ω band and both quote 50 Ω, which covers that row. The other applicable requirements still need review.
The device provides adjustable internal capacitance. The default 7 pF on the reference design includes its parasitics, and CCFG lets software change the connected capacitor setting. Fitting an 8 pF crystal does not automatically set the board to 8 pF. Record the calibration load of the quoted crystal, the CCFG setting, the board revision and the evidence for effective load. This avoids using one material approval for different firmware images with different loading.
Recalculate the motional-inductance requirement
TI states that the crystal manufacturer's specification must meet a motional inductance below 3 × 10⁻²⁵ divided by the square of load capacitance in farads. At 7 pF, this is about 6.122 mH. At 8 pF, it is about 4.688 mH. Two hypothetical quotes both guaranteeing at most 5.5 mH would therefore leave about 0.622 mH of margin at 7 pF and miss the 8 pF condition by about 0.813 mH. Convert picofarads to farads before calculation. Entering the bare numbers seven and eight would give meaningless results.
If the supplier provides an equivalent circuit fitted to a single unit, confirm that the reported value is motional inductance and record the fixture and method. Request a production limit for the full part number, applicability and drive conditions. Keep any sample distribution and original measurement traces. If only a typical value is available, proceed with engineering samples where useful and leave the guaranteed limit unresolved on the first-article report.
For a candidate near the calculated bound, ask how the nominal load and its tolerance are defined. At 7.5 pF the expression gives about 5.333 mH, nearly 0.79 mH lower than the 7 pF result. If the design file uses one number for the internal setting, board parasitics and component specification, have engineering identify the load used in TI's expression and verify board settings. A component report for one nominal load should not transfer automatically to a board with different parasitics. Keep the component measurement and actual board configuration separately traceable.
A report may also put motional capacitance in a generic “capacitance” field. It belongs to the equivalent circuit and is much smaller than typical load capacitance. It cannot replace CL in the expression. If the supplier provides the series frequency and motional capacitance from a consistent fitted model, they can support a check of motional inductance. Keep sample estimates distinct from a production guarantee. Check that resistance, inductance and nominal load refer to the same part and sample, with fixture calibration identified.
Plan a safe start-up observation
TI's 200 µs start-up entry is typical and refers to its Power driver. When firmware or the circuit changes, measure the interval from the relevant start event to a usable system clock. The data sheet also warns against probing or stopping the crystal while the DC/DC converter is enabled because this may permanently damage the device. Use a reviewed status, buffered diagnostic signal or safe bench method. Do not hook an ordinary probe onto the running oscillator nodes in that configuration. Establish the board-level test method before treating an incoming component reading as system evidence.
At receiving for the 48 MHz passive crystal, confirm the complete part, frequency, resistance, motional-inductance limit and load. Retain the CCFG setting and supply with the actual board revision, then validate cold start and radio operation using the approved method. Approve the 7 pF option only for its tested assembly and firmware. If the 8 pF option lacks the required inductance evidence, request a suitable configuration or a separate engineering change. Two quotes sharing a 50 Ω value do not establish reciprocal interchangeability.