Selecting a 19.2 MHz TCXO for battery operation requires checking current and phase noise under the relevant conditions. TKD’s TC-3225HP page lists nominal frequencies from 10 to 52 MHz and gives phase noise at a 19.2 MHz carrier, at 1 kHz offset. The operating-current row is limited to 26 to 52 MHz. The series covers 19.2 MHz, but that current figure does not apply there.
Find evidence for each acceptance item at the actual frequency
Record carrier frequency, offset, supply, output type, and load. Keep the conditions with each limit. An applicability column can identify the phase-noise row as using a 19.2 MHz carrier and prompt a check of whether the value is typical or guaranteed. Mark current as pending and request the maximum and its measurement conditions for the desired carrier and supply. Published family coverage does not establish every specification for every option.
Measure battery current and phase noise separately
Isolate the oscillator supply branch to measure steady-state current with the design load. Keep supply voltage and startup current separately. For phase noise, record the 19.2 MHz carrier, offset, instrument noise floor, and any measurement buffer. If acceptance is based on integrated jitter across a band, request a phase-noise trace or the relevant integration result. One 1 kHz datum cannot supply the integral.
If only a few samples are available, use their readings for prototype battery estimates and leave the production limit pending. At design freeze, verify that the formal specification for the order code includes the required conditions. Record the distinction between working samples and enforceable production limits. TKD TC-3225HP manufacturer specification