Two radio boards use 24 MHz and 26 MHz, and engineering wants to raise both operating limits to +105 °C. Epson's TSX-3225 configuration guide lists options by frequency and temperature range. The 20G row specifies −40 to +105 °C and ±20 ppm, with a parenthetical restriction to 20 MHz and 24 MHz. Although 26 MHz lies within the general series range, that row does not establish availability of the same grade at 26 MHz. Keep two RFQ lines so the exception is not lost when the table is copied.
Include the parenthetical restriction in the RFQ
State the exact frequency, operating temperature range, required temperature stability, initial tolerance and load in the RFQ. Request complete order information for 24 MHz. Ask separately whether Epson supports the 26 MHz configuration or another series. If the supplier recommends a different series, ask for documentation showing the frequency and temperature range together. A storage rating of +105 °C alone does not establish that the part operates there within the required error.
Confirm the operating limits before considering a common part
Ask thermal engineering whether the requirement applies to the component location or ambient temperature and whether short excursions and sustained exposure have different limits. If both boards should use the same grade, identify who approves the error allocation. Put the temperature range, frequency, type of limit and manufacturer's source on one line for engineering approval.
If samples are tested only to +85 °C, state that limit in the report. Track higher temperatures separately against the specifications and qualification plan. Keep the footnote and document revision in purchasing records so 20G remains traceable to the frequencies it actually covers. Epson configuration guide, TSX-3225 page