An original USB dock uses a 24 MHz passive crystal. Its next revision uses an active oscillator at the same frequency. Both boards read close to 24 MHz, and a keyboard works on either. The revised dock later behaves intermittently with a USB 3.0 storage device. This does not by itself identify the oscillator as the culprit, but a low-speed test is insufficient to qualify the change. TI gives the TUSB8041 separate requirements for a crystal and an external clock. Start with the input interface and then ask for jitter evidence that matches the device requirement.
The two 24 MHz options need different purchasing specifications
The TUSB8041 crystal circuit uses a 24 MHz fundamental-mode crystal and an external load network. TI lists a load capacitance range of 12 to 24 pF and recommends a maximum ESR of 50 Ω or less. This is not an instruction to freely exchange any two loads within that range. Check the specified load for the full part number against the board components and parasitics. If an original crystal was qualified at 18 pF and a candidate is specified for 12 pF, verify frequency deviation and cold start again, even though both loads fall in the listed range.
For an external clock, the same data sheet shows a 1.8 V clock source driving XI with XO left open. Verify the actual output and the receiving conditions when ordering a 24 MHz active oscillator. The assembly drawing should state what is fitted and omitted if the former crystal and capacitor pads remain. The module already produces a digital clock, so the crystal network needs a deliberate assembly decision. Check supply and output options and make sure the tolerance and jitter report is for that order configuration.
Frequency deviation and jitter tell you different things
At 24 MHz, one ppm is 24 Hz. The ±100 ppm scale corresponds to ±2,400 Hz from nominal. A hypothetical reading of 24,001,200 Hz is 50 ppm high under the stated test conditions. This is one measurement. For qualification, include the relevant temperature range, aging, supply conditions, and remaining system budget. A room-temperature reading cannot establish the full guarantee. A satisfactory average frequency also does not establish edge timing.
For an external clock source, TI lists either absolute peak-to-peak jitter below 50 ps or peak-to-peak jitter below 25 ps after applying the USB 3.0 jitter transfer function. Each limit goes with its method. A hypothetical 44 ps unprocessed result requires confirmation that it was measured as the specified absolute peak-to-peak quantity. A supplier’s RMS integrated phase-jitter number is a different quantity, even if numerically smaller than 25. Ask for the method, observation interval, reference conditions, and measurement point before deciding which criterion is supported.
Give the receiving test three separate entries
For frequency, record test point, temperature, supply, instrument reference, and observed result. State whether it is a single-point reading or part of a qualified range. For the interface, confirm that the 24 MHz oscillator produces acceptable high and low levels at XI under the actual load. Keep the probe loading under control and document its setup. Different grounding and threshold methods can change measured jitter. For jitter, preserve the units and the exact processing method. Put each report in its corresponding field so peak-to-peak and RMS results are not compared directly.
The passive-crystal record needs the actual oscillator network and startup evidence. Compare cold power-up, reset, and sustained operation after changing parts. Adding probe capacitance to a crystal node can change the frequency or startup. Start with a suitable buffered observation or a system-level check. Use a characterized low-loading connection if direct probing becomes necessary. Keeping both setups in the record lets the next engineer identify whether a change came from the component or from the measurement.
Qualify the replacement in the product
Compare the old and new assemblies using the same USB 3.0 peripheral, cable, and port configuration. Record the actual negotiated speed, repeated connection behavior, and whether the product meets its high-speed acceptance requirements. Verify USB 2.0 and SuperSpeed separately where the setup supports both. A storage device can remain usable at a lower negotiated rate, so a successful file copy only proves that a transfer occurred. Record the reported link speed separately from the peripheral’s rated capability and rule out a cable or port fallback.
Passing with a low-speed peripheral leaves high-speed behavior and timing to be checked. If high-speed problems appear, investigate supply and signal integrity along with the clock. A purchase change should have evidence for the exact order code, input interface, frequency budget, jitter requirement, and the board-level result.
For production, agree on who keeps the raw measurement. Specify the supply, package, and output option used in both sample and production orders. Describe whether the test was measured at the module or the receiving pin. If a supplier later changes the output or a configuration suffix, that record shows which acceptance tests to repeat.