Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Sourcing 96 MHz TXC crystals in a 2016 package: why 7R and 8Y need separate RFQs

An RFQ that says “TXC, 96 MHz, 2016 passive crystal” gives purchasing enough information to shortlist a series. TXC lists both 7R and 8Y with a 2.0 × 1.6 mm body. The 7R series spans 20–64 MHz, and 8Y spans 16–96 MHz. Of these two series, 8Y is the candidate for a 96 MHz RFQ. To quote a part, obtain its complete ordering code and confirm that its electrical and mechanical specifications meet the requirement at 96 MHz. For an existing board, also retrieve the original crystal part number and host chip model. TXC MHz crystal catalog.

Find out where the 96 MHz clock is used

Two designs can show 96 MHz in their documentation. One may explicitly require a 96 MHz crystal in the host chip’s external oscillator circuit. In another design, 96 MHz might appear in the system clock tree. For example, if the chip supports a 24 MHz crystal reference with a PLL configured to multiply by four, the crystal on the board is a 24 MHz part. Those two requests lead to different shortlists. Use the crystal designator, the host’s oscillator pins and the clock tree to identify the frequency at the crystal itself. Use MHz consistently in the RFQ and put the initial tolerance and other error limits in separate fields.

The two series datasheets overlap at frequencies such as 24 MHz and 64 MHz. At 96 MHz, 8Y is at its published series ceiling. If an existing assembly uses a 64 MHz 7R and an 8Y is proposed at the same frequency, compare the two exact parts for load capacitance, equivalent series resistance and PCB lands. If a legacy BOM lists “7R” and “96 MHz” on the same row, check a previous reel label or approval drawing to see which entry needs correction. TXC 7R series datasheet and TXC 8Y series datasheet.

Read the frequency band that covers 96 MHz

The 8Y electrical table lists ±10 ppm initial tolerance for 16–60 MHz and ±15 ppm for frequencies above 60 MHz. The initial measurement temperature is 25 ± 3 °C, so 96 MHz belongs to the second row. The table gives temperature stability relative to 25 °C, with ±20 ppm over −40 to +85 °C and ±30 ppm over −40 to +105 °C. When requesting a 96 MHz ordering code, specify the operating range and allowed frequency error together. Ask the supplier to confirm the available combination on the approval drawing for that code. TXC 8Y series electrical specifications.

At 96 MHz, 1 ppm equals 96 Hz, so the table’s ±15 ppm initial tolerance converts to ±1,440 Hz. Suppose a product allocates ±25 ppm, or ±2,400 Hz, to this entire reference. The initial tolerance alone could consume 15 ppm. If the ±20 ppm temperature term for the +85 °C range is used for screening and the two errors have the same sign, the first-order sum at the nominal frequency is 35 ppm, about 3,360 Hz. The example shows why an RFQ needs to specify whether its ppm limit covers initial tolerance at room temperature or total error across temperature. For final approval, use the exact part’s limits and include the effects of actual loading and aging as the product requires.

Check the PCB lands and installed height

The 2016 designation places the body at about 2.0 × 1.6 mm in plan view. Use the drawings for the two complete ordering codes to compare their outlines, terminal positions and sizes, recommended lands and stencil apertures. Check the drawing’s viewing direction before reading the pin numbers. Identify the terminals that connect to the host’s oscillator pins and check the manufacturer’s instructions for grounding or leaving other terminals open. Even if four terminals appear to line up in a drawing, verify their functions against the PCB netlist. This review tells the board and assembly teams whether they need a layout change, stencil change or another placement trial.

The TXC 8Y series datasheet lists a nominal body height of 0.5 mm. Suppose the board surface is only 0.55 mm below a shield. Subtracting the nominal height leaves 0.05 mm of nominal clearance. The maximum body height, soldered standoff, PCB and shield tolerances all affect the installed clearance. Have the mechanical team evaluate the maximum assembled height against the minimum available space and check for interference on samples where needed. Include the installed height limit in the RFQ when it constrains the assembly. TXC 8Y series package dimensions.

Write an RFQ that leads to a traceable sample

Put the requested part and the engineering criteria on the same line. Start with “96.000 MHz passive quartz crystal, TXC 8Y series pending confirmation, 2.0 × 1.6 mm.” Add the required temperature range, initial tolerance, temperature stability, load capacitance CL, maximum ESR and drive-level requirement. If the host requires fundamental or overtone operation, include that condition too. CL is the specified load condition for the crystal. Engineering should check it against the actual chip and external capacitors. ESR and drive level matter for startup margin and power in the crystal, so use values applicable to the code and frequency being offered.

Ask for the full ordering code, its approval drawing, and separate sample and production supply terms. If the reply only confirms “8Y can reach 96 MHz,” record the series coverage and leave the exact code, CL, tolerance over the requested temperature range and lead time pending. If the supplier proposes a different suffix, ask for that code’s drawing revision and the differences it introduces. Engineering can then determine whether both samples can use the same test setup. State the sample quantity and expected production quantity separately and ask for the supplier’s written reply on delivery and availability for the proposed code.

Qualify the samples on the actual assembly

Check the sample label for the exact code and lot, and review its dimensions against the drawing. Use the intended PCB, host chip and firmware. Repeat power-on starts at the product’s supply and temperature limits and record oscillator ready status, startup time and frequency. If a verified buffered clock output is available, record its divider or multiplier and calculate the oscillator reference frequency from the reading. Measuring at that output avoids adding probe capacitance directly to the oscillator nodes. Check the actual clock source, especially if the firmware can fall back to an internal clock.

When qualifying a replacement for an older board, compare samples and the original part under the same conditions and check soldering and installed clearance. A useful status to give the customer is “8Y series covers the frequency, exact code and drawing pending.” Once a drawing is available, update the status to identify that code and the remaining board validation. Keep the sample lot, drawing revision, PCB revision and test results together so purchasing can order the part that engineering actually qualified.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.