Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Why a 2.8 V quotation for a TXC 7N 40 MHz TCXO still needs the pad count

Two revisions of a test instrument use a clock position described as 7050. Engineering is sourcing a 40 MHz TCXO for the low-voltage board. Both quotations say TXC 7N, with the same apparent size, frequency and stability. One says 2.8 V and the other offers a wider supply range. TXC's catalog has a four-pad 7N and a ten-pad 7N, and their listed supply choices differ. Match the package underside, supply guarantee and output to the actual board before approving either quotation.

Connect the family entry to the device and board

The precise TCXO catalog lists both 7N versions as 7.0 × 5.0 mm and 10 to 52 MHz, showing ±0.28 ppm over −40°C to +105°C and CMOS or clipped-sine output. The four-pad row lists 2.5 V, 2.8 V, 3.3 V and 2.25 to 3.63 V. The ten-pad row lists 2.5 V, 3.3 V and 2.25 to 3.63 V. The wide range includes 2.8 V numerically. The ten-pad row does not separately list a nominal 2.8 V option. Ask whether the quotation is for the four-pad nominal option or for a wide-range configuration with applicable documentation. Forty megahertz lies in the family range. The exact ordering combination still requires an acknowledged part number and specification.

TXC's quality documents identify ten-pad and four-pad 7N devices in the report coverage. This supports the distinction between the two variants. Use device-specific electrical and package drawings for production. If an internal description only says 7050 and 40M, obtain the outline, underside pin assignment, recommended land pattern and original label. Review ground, supply, output and the other pads using the applicable drawing. Another 7050 TCXO's pinout is insufficient. If both can be placed on a shared layout, document the compatible pattern and qualify both assemblies.

Estimate the minimum pin voltage and verify the guarantee

Suppose a 2.8 V board uses a regulator with ±5% steady-state error. The output spans 2.66 to 2.94 V. If loading causes a further 60 mV drop between that output and the device, the illustrative minimum at the pin is 2.60 V. If a particular specification guaranteed only 2.8 V ±5%, its lower limit would be 2.66 V and this board would be 60 mV below it. A confirmed 2.25–3.63 V configuration would have 0.35 V of room to its lower limit. The ±5% is hypothetical, not a TXC tolerance for every nominal 2.8 V option. Verify the actual waveform at the oscillator pin during board testing.

At 40 MHz, 1 ppm equals 40 Hz. The catalog's ±0.28 ppm is ±11.2 Hz. If the receiver allows ±15 Hz for the entire reference, that conversion shows the allocation needed for the catalog item. Check the exact data sheet to determine whether initial offset, supply, load, reflow and aging are included or specified separately. Keep the supply, load, elapsed time and temperature range with each result before treating it as a total or adding separate items.

Lock the output and supply in the order record

Test a board of each relevant revision. Measure voltage and clock at appropriate points during normal operation, cold start and load transients. Verify that the downstream receiver accepts the output and note when frequency reaches the system requirement. A 40 MHz clipped-sine output and a CMOS output need different attention to load and receiver thresholds even when the nominal frequency is identical. Obtain the applicable output swing, test load, pin drawing and supply conditions for the exact option.

A test board may share its reference supply with the downstream comparator. A load transient can change receiver thresholds at the same time as it changes the clock supply. If a counter at the oscillator continues to see clocks while the receiver misses a pulse, check the supply, output and receiver separately. Do not record every missed pulse as oscillator stoppage. If the two packages need different physical probe points, choose suitable buffered observation nodes and compare using the same independent reference. A wide supply option does not establish the board's entire transient and start-up sequence.

Ask each supplier to provide applicable minimum and maximum operating voltages with the frequency and temperature conditions. Keep a nominal-only response distinct from a documented wide-range response. Assembly can establish bottom-view and label checks while engineering approves the actual output and supply. If two options reach production, identify the approved board revisions beside each complete number. Receiving can then select the correct reel without relying on the shortened family name.

Release the volume order against the complete number and its manufacturer specification, including pad count, land pattern, guaranteed supply, output and test conditions. If the quotation has only a nominal voltage or an ambiguous pad count, use samples for engineering while those fields are being verified. Keep an approved older board for comparison during transient and loading tests. A later change to supply or output can then be checked against the part actually released.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.