Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

TXC 7Z20070001 has two frequency reference points. Which one governs incoming inspection at 20 MHz?

A legacy instrument uses a 20 MHz temperature-compensated oscillator under the TXC approval number 7Z20070001. A revised BOM says only “7Z, ±0.5 ppm.” A buyer following today's family table is offered a 1.8 V candidate, while receiving applies the ±0.5 ppm figure to room-temperature results and rejects samples more than 10 Hz from nominal. Restore two items from the old records before assembling: the exact part's supply range and the reference point for each frequency limit. This keeps voltage variants apart and gives incoming and final inspection the same frequency definitions.

Read the family table and exact approval at their respective levels

TXC's online TCXO table describes 7Z as 2.0 × 1.6 mm, 10 to 52 MHz and shows options including 1.8 V and ±0.5 ppm. The manufacturer-authored S1 document attached on TI E2E records the exact 7Z20070001. It specifies 20 MHz, 3.00 to 3.60 V with 3.3 V typical, and operation from −30 to +85 °C. A 1.8 V family summary and a 3.3 V historical approval can coexist because they describe different scopes. For repair, compare the reel, past purchase line, board regulator and actual load. Get the applicable specification revision for the orderable part being delivered. The public approval helps identify the original configuration and does not confirm this delivery by itself.

Check pin 1 against the same approval. S1 gives ground or NC for pin 1, ground for pin 2, clipped sinewave on pin 3, and supply on pin 4. If a candidate uses pin 1 for standby or voltage control, the old board's ground connection could change its state or drive it outside the required frequency range. A four-pad outline and 20 MHz marking only start the comparison. Read the bottom view and output definition for the complete number and check both supplies. A typical 3.3 V condition should not be combined with another suffix's voltage or control behavior.

Record the reference for each frequency deviation

S1 specifies ±1.5 ppm initial tolerance after two reflows and defines it relative to nominal. The −30 to +85 °C stability is ±0.5 ppm relative to the individual unit's frequency at 25 ±2 °C. It separately lists ±0.1 ppm for the specified load change and ±0.1 ppm for the specified supply change. At 20 MHz, one ppm is 20 Hz. The initial allowance is ±30 Hz and temperature deviation is ±10 Hz from that unit's room-temperature value. A sample that is +22 Hz after reflow and moves a further +7 Hz in the chamber reads +29 Hz overall. The two measurements pass their respective 30 Hz and 10 Hz limits in this example.

For an illustrative worst-direction board budget before initial calibration, add 1.5, 0.5, 0.1 and 0.1 ppm, giving ±2.2 ppm or ±44 Hz. Including the table's first-year room-temperature aging allowance of 0.2 ppm gives ±48 Hz. This is a design estimate built from terms under their specified conditions. Verify any combined manufacturer guarantee, aging conditions and actual load separately. If production removes initial offset against an external reference, take the corrected portion out of the later error budget and keep calibration residual. A calibrated temperature excursion of 10 Hz cannot serve as the incoming limit for all uncalibrated parts.

The same distinction applies to supply testing. At 3.3 V, the specified ±5% supply change spans 3.135 to 3.465 V, which is the condition for the voltage-related stability term. Although the electrical table spans 3.00 to 3.60 V for operation, do not extrapolate that stability term to a wider voltage range. If the instrument settles at 3.05 V after switching to its battery, it remains inside the operating range but falls below the conditions listed for the frequency term. Test this as a separate condition, check the settled frequency and clock continuity, and request the applicable limit for 3.05 V.

Reproduce the test load and keep separate board and chamber records

The manufacturer shows a 1,000 pF DC-blocking capacitor in series with the output, with nominal load 10 kΩ in parallel with 10 pF. If the same samples support component and system qualification, retain separate records for each unit. Record load, supply, reflow count, observation point and frequency reference for the component. Record receiver input and conditioning on the assembled board. Directly connecting a 50 Ω scope places a much heavier resistive load on the output than the nominal 10 kΩ and can pull the amplitude down. A device that passes on the component fixture but fails in the system calls for checking receiver levels, bias, edge rate and measurement technique.

Release incoming material against its room-temperature initial tolerance first. For chamber results, subtract each unit's own room-temperature reading obtained under matching conditions. If temperature return creates a different reading, preserve the ramp direction and dwell time instead of signing off on an average. Where the customer has materials requirements, locate the 7Z group in TXC's quality index and confirm the applicable document revision and lot scope. Source legacy parts by the complete approval number and its conditions. The family description can begin the search for candidates.

Manufacturer references

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.