A customer asks for a materials test report for a 32.768 kHz crystal. The supplier sends a tuning-fork report from the same manufacturer with 9H in its name. The first question is what the report’s samples cover. TXC lists separate reports for tuning-fork crystals of different sizes. Copying a previously approved document to a procurement record with a new part number can associate it with the wrong package. When the customer asks about the plating or seal, a reel certificate on its own may not establish what was sampled.
Use the actual package to identify the report group
TXC’s product search identifies the 9H T11 as a 2.0 × 1.2 mm 32.768 kHz crystal and the 9H T12 as a 1.6 × 1.0 mm crystal. Both entries list ±10 and ±20 ppm options. TXC’s quality-document page labels the T11 tuning-fork ICP report 2012 and gives the T12 report a separate 1610 entry. These four-digit designations correspond to package sizes. Maintain distinct fields for package, report date, and the reel date code. The index helps identify the group. To cite a report against shipped material, compare its full contents, the purchase part number, and the supplier’s written coverage statement.
Suppose a board revision changes its 32.768 kHz crystal from T11 to T12. Obtain the report IDs, sample descriptions, and photographs. Determine whether the newer package’s base, terminals, or seal is named in its report or covered by a manufacturer statement. Even if both summaries report a pass, read the sample description, material layers, and test method. If a report identifies samples only by the manufacturer’s internal codes, ask for a documented mapping to the full orderable part number and material revision before quality approval. Keep the document ID and date so the evidence can be retrieved when the packaging form or ordering part number changes again.
Distinguish a whole-device sample from a homogeneous material
The EU RoHS Directive expresses maximum concentrations by weight in homogeneous materials. Consider the general Annex II lead limit of 0.1%, equivalent to 1,000 mg/kg. In a hypothetical example, a component weighs 10 mg, one homogeneous layer weighs 0.5 mg, and the layer is 0.2% lead. Assume zero lead elsewhere. The amount of lead is 0.5 mg × 0.2%, or 0.001 mg. Dividing by the complete 10 mg device gives 0.01%, or 100 mg/kg. A whole-device result is below 1,000 mg/kg, while the layer itself has 2,000 mg/kg. The example explains why quality needs the lab’s sample preparation details. It does not describe TXC material composition or determine whether an exemption applies.
Retain the detection or quantification limit, substances tested, units, and sample preparation. When a report says nondetect, inspect the lab’s definition. For example, if the customer limit is 100 mg/kg in a material and an applicable method and sample show less than 50 mg/kg, the result supports a value below the limit. A result of less than 200 mg/kg still allows a concentration between 100 and 200 mg/kg. Request a lower reporting limit or other evidence. A zero entry in the receiving record would misstate the report. Check whether surface material, ceramic, and other materials are separately described. For a missing layer, request the sampling procedure and find out which layers the manufacturer’s statement covers.
A lab may collect the same homogeneous material from several matching units to obtain enough sample mass. Check sampling positions and pooling rules. If each unit yields 0.5 mg of the same layer and the method requires 10 mg, the ideal minimum is 20 units. At 80% recovery, expect about 0.4 mg per unit and at least 25 units, plus any retained samples. Ask the lab to confirm the quantity for its method. Specify which part numbers, lots, and layers may be pooled before submission. One result from a mixed sample of two part numbers and three lots cannot establish that each passed. Give old and new material separate sample identifiers and keep the bagging record.
Verify traceability at receipt and review every package change
For first approval, obtain the complete 32.768 kHz orderable part number, applicable 9H T11 or T12 series, sample report, and statement linking it to the material. Create a controlled list of attachments with the issuer, sample date, document revision, and customer-specific terms. When the supplier provides an updated report, the report ID and sample fields show whether it only has a new issue date or covers different materials or samples. Retain the evidence for earlier approvals. Verify the revision for the current order before changing the approved reference for receiving.
At receipt, check the part and label against the approved part number and drawing. Use the approved part mapping or manufacturer confirmation to connect the reel and report. If the material documentation is flagged for review, keep the electrical test data. These checks can appear on the same work order and each has its own acceptance evidence. When a new package passes the pilot frequency and startup tests, quality still reviews its material coverage. A complete materials file also leaves the load capacitance, frequency, and oscillator startup checks to the part and board test plans. If a customer later asks about a lot of 32.768 kHz crystals, procurement can identify what was sampled, how the values were calculated for the materials, and why the report applies to the reel.