A board in an outdoor enclosure looks safe on the basis of outside air temperature. The air near its oscillator reaches the mid-90s Celsius. The RFQ specifies a TXC OH 10 MHz OCXO in a 7 × 5 mm package, but two quotes give different temperature and stability figures. TXC lists OH in two product groups with overlapping package and supply options. Establish where and under what operating conditions the equipment temperature was measured, and link the required grade to the full part number. A few devices that continue to oscillate above a published limit cannot establish the rating of future lots. Start with the equipment’s original thermal measurements before comparing the quotes.
TXC lists the same OH series name under two product groups
The TXC OCXO page lists a 7 × 5 mm OH in its Miniature ThermSymEros group, with a 10 to 50 MHz frequency range, ±20 ppb stability, and an operating temperature range of −40 to +85 °C. The Reliable ThermSymHercules group also lists a 7 × 5 mm OH, with a 10 to 54 MHz range, ±10 ppb stability, and −40 to +105 °C. Both rows show a CMOS output and list 3 V, 3.3 V, and 2.97 to 3.63 V among the supply entries. Use the group listings for initial selection. Ask the supplier to identify the full part number, its product group, and the actual supply range for that code.
Tie frequency stability to its temperature range in the RFQ. At 10 MHz, 20 ppb is 0.2 Hz and 10 ppb is 0.1 Hz. Suppose the system allocates ±0.15 Hz or 15 ppb to temperature. If the supplier confirms both figures with the same basis, the 20 ppb grade exceeds the allowance by 0.05 Hz and the 10 ppb grade leaves 0.05 Hz. Ask what reference was used for these figures, such as room temperature, a fitted value, or another defined baseline. Establish the applicable voltage, load, and warm-up conditions. Give initial setting, aging, and measurement error their own entries in the system budget as applicable.
The chamber can be at 90 °C while the oscillator’s location is at 96 °C
Suppose the intended maximum external ambient temperature is 65 °C. At full load and a specified fan speed, a reference measurement near the oscillator is 27 °C above the enclosure reference, giving 92 °C. Add 4 °C as an allowance for measurement and operating variability. The selection limit of 96 °C is 11 °C above the 85 °C grade and 9 °C below the 105 °C grade. This is an illustrative selection calculation. Before setting test points, ask whether the manufacturer defines operating temperature as local air, a prescribed location near the device, or another test position. The oscillator controls its internal oven temperature, which is distinct from the temperature near the board.
Record enclosure reference temperature, local air temperature, and case temperature when needed. A sensor attached to the heated case can read several degrees differently from nearby air. Keep photographs of probe positions, mounting method, fan and load conditions, and the stabilization interval. If a chamber setpoint is 90 °C and the board reference is 96 °C, use the board reference for the grade decision when that is the agreed measurement position. Verify cold startup and frequency on heating and cooling. A trace on the way up does not describe the device’s path as it cools.
If the enclosure can derate after a fan fault, account for the oscillator’s conditions in that state. In an illustrative case, with the outside air still at 65 °C, reduced fan speed raises the local rise to 37 °C. Adding the 4 °C allowance gives a selection point of 106 °C, one degree above the Reliable grade. Send the required functions and duration in derated operation to thermal and timing engineering. If the equipment turns off a high-power function before reaching the limit, verify the actual threshold and the maximum local temperature after derating. If timing must continue throughout the fault state, engineering needs a cooling change or a part with evidence for that condition. Treat any short excursion separately in the supplier agreement.
Link the high-temperature condition to the purchase code and inspection record
When a supplier confirms the +105 °C grade, obtain the full manufacturer part number, its drawing, and the stability conditions with the quote. Verify the sample label. At receipt, check the code, package, and supplier records against the order. Hold a lot for identification if the paperwork only says OH. If +85 °C material is available for a layout or soldering pilot, use a controlled pilot authorization and record the actual part number in the sample report. Observations of those samples at 96 °C can be retained, but production approval needs the intended orderable configuration tested under the agreed conditions.
A qualification report can retain absolute frequency and change from the reference temperature. Suppose a stabilized unit reads 10,000,000.12 Hz at 25 °C and 10,000,000.21 Hz at the highest project operating point. The change is 0.09 Hz or 9 ppb from the 25 °C reading. Its error from nominal is 21 ppb. If the supplier’s temperature criterion is referenced to the initial room-temperature reading of the same unit, evaluate the 9 ppb value with measurement uncertainty. Apply any separate absolute frequency limit to the 21 ppb value. Keep both results and their conditions with the full ordering code. When another quote says OH, this record identifies the approved grade and the basis on which it was tested.