Replacing a 24 MHz active oscillator with 52 MHz on the USB3320. How much faster is suspend recovery?

A USB3320 design needs faster recovery from suspend. Procurement receives a proposal to replace its 24 MHz active oscillator with a 52 MHz active oscillator. Both are supported reference frequencies in the relevant mode, but the timing budget must use the manufacturer's measurement origin. Microchip measures suspend recovery from reference clock start to DIR deassertion. Time for the oscillator to wake or power up can precede that interval. Buying from the shorter row in the data sheet alone can leave the assembled board outside the host timeout.

Identify which clocking mode the board actually uses

Microchip describes separate ULPI clock output and ULPI clock input modes. In output mode, the PHY produces the ULPI interface clock from a local reference. REFSEL is 111 for 24 MHz and 000 for 52 MHz. The input mode takes an external 60 MHz reference and has separate conditions. Before approving an alternate, identify the reference source, which side drives the interface clock and the actual strap settings. Save them with the board revision. An identical strap pattern on a different mode is interpreted using its own rules.

Here the material change is for the external reference. An existing 24 MHz passive crystal across the oscillator pins and its load capacitors would be a separate circuit. An active source needs its single-ended path and level verified. Check the data sheet and design checklist for the unused oscillator output, which is left open in that arrangement. Cross-reference signal names with the actual package pin table. Specify a surface-mount active oscillator with supply, output, enable, load and temperature on the quote, then sample against the approved schematic. The passive crystal's load and drive data do not describe the active clock waveform.

Add delays from the correct trigger

Microchip gives typical and maximum suspend recovery of 1.12 ms and 2.37 ms for 24 MHz, and 0.52 ms and 1.77 ms for 52 MHz. Its footnote defines the interval from reference clock start to DIR deassertion. The maximum improves by 0.60 ms, as does the typical figure. Budget with maxima when a user-facing deadline or host timeout must be guaranteed. A measurement triggered by a late interrupt can miss the start of oscillator and PHY recovery. Establish the trigger before comparing the result to the table.

Suppose the board must release DIR within 2.10 ms of the wake request. Assume 0.25 ms maximum for the oscillator to produce its specified waveform and 0.10 ms for control logic, all in sequence. The example total is 2.72 ms with 24 MHz and 2.12 ms with 52 MHz. The latter is faster but still 0.02 ms late, before any further measurement allowance. Holding the other assumptions fixed leaves at most 0.23 ms for the 52 MHz oscillator to produce a valid clock. Confirm any overlap on one capture instead of assuming the intervals occur in parallel.

Some systems keep the clock source powered and gate its output. Others switch off the rail. Ask for separate definitions of enable-to-valid output, standby recovery and startup from a valid supply. If the supplier's timing origin differs from the system wakeup trigger, account for the extra interval. Where a regulator powers up the oscillator, capture rail, enable, REFCLK and DIR together. Mark when the waveform actually reaches acceptable swing and frequency.

To isolate a failure, give the same board revision a compliant continuously running reference, then restore the oscillator under its actual control path. The continuous source still has to use the approved input. It shows whether PHY and host cooperate with reference already present. If only the onboard source fails, examine wake control, supply and early pulses. If both fail, revisit straps and host state. This comparison is more informative than changing the frequency alone.

Apply the supplier guarantees at the appropriate step

Ask for the 52 MHz timing maximum with its voltage, temperature and load conditions. A typical value can guide samples while a guaranteed candidate is sourced for the worst corner. The manufacturer also lists reference accuracy and duty-cycle requirements to carry into the board inspection. A running interface clock does not establish compliant resume timing. If the host depends on a hardware or software auto-resume flow, use the production settings and capture entry to suspend, the wake request and the first useful transaction.

The data sheet’s ±500 ppm reference limit corresponds to ±12,000 Hz at 24 MHz and ±26,000 Hz at 52 MHz. It is an input boundary. A project can allocate a stricter limit to its shared clock path. Record steady-state frequency separately from startup behavior. Short pulses, partial swing or an unsettled frequency can delay the first clock the PHY can actually use. Put the conditions in the sample request so the vendor does not equate initial activity with valid output.

On the change record, identify reference frequency, straps, clock category, exact part and recovery mode. Incoming inspection should verify whether the approved part is the 24 MHz or 52 MHz active oscillator. Then qualify system timing at low supply and temperature limits. If the source passes its individual limit but the host still times out, hold the qualification and budget from the system's actual start and end events. This preserves both the device specification and the assembled-system acceptance condition.