A 100 MHz VCXO tunes ±80 ppm on the bench. Why ask for its APR?

A room-temperature voltage sweep shows a 100 MHz VCXO tuning 80 ppm to either side of nominal. The equipment needs to track ±60 ppm over its service conditions, and the sample result looks sufficient. Check whether the quotation describes the range actually seen in that one sweep or the guaranteed controllable range over the specified conditions. The results answer different questions.

APR is absolute pull range, the guaranteed range that remains controllable around nominal. The Epson VG5032VFN 100.000000 MHz CJGHBA specification identifies a 5.0 × 3.2 × 1.3 mm package, LVDS output, 3.135 to 3.465 V supply, and a control range of 0 to 3.3 V. Section 5 lists a minimum APR of ±50 ppm for the cited configuration and defines it relative to control range and frequency tolerance. Section 4 includes the effects named there, such as initial tolerance, temperature, supply, and aging under the stated conditions. Compare definitions between suppliers before comparing ranges.

Put the three ranges in separate rows

At 100 MHz, one ppm equals 100 Hz. A room-temperature sweep of ±80 ppm therefore spans 99,992,000 to 100,008,000 Hz. If a hypothetical operating condition shifts that curve upward by 30 ppm without changing its span, it covers −50 to +110 ppm. A downward shift of the same amount gives −110 to +50 ppm. The common symmetric interval is ±50 ppm. This hypothetical example shows how margin can shrink. A single sample and an assumed drift are not a supplier guarantee.

The cited Epson configuration specifies ±50 ppm APR, or ±5,000 Hz at 100 MHz. A specified need for ±60 ppm, or ±6,000 Hz, is not demonstrated by that APR. Conversely, where a supplier states that APR already allows for the appropriate frequency-tolerance terms, avoid deducting the same terms again. Keep the guaranteed device range, required tracking limits, and board control-voltage range separately.

Input requirements may be asymmetric. An example needs −30 ppm on one side and +55 ppm on the other. A report of total width alone can hide the failure to reach one endpoint. Record both limits relative to nominal and verify both at the pertinent temperature and supply.

Use the voltage actually reaching the control pin

A bench supply can reach the datasheet endpoints, whereas an assembled DAC may only deliver 0.2 to 3.0 V. Measure the real board endpoints and corresponding frequencies. Record probe loading, buffer action, and settling time. A full-range linearity specification does not make every local slope identical. Use sample sweeps as engineering evidence and the exact ordering specification for the production guarantee.

For qualification, identify where each reading was taken. A control voltage observed at a DAC output can differ from the voltage at the device after a protection network. Save both readings when the system margin is small.

If a quotation gives only a room-temperature tuning span, request guaranteed limits, allocation of frequency tolerance, control voltage, and test conditions. Record endpoints and center at the temperatures and supplies agreed for the equipment. A PLL also depends on tuning response, gain, and interface behavior. Keep separate evidence of acquisition time and behavior during reference changes.

The Epson configuration uses base code X1G0054810008xx. Suffix 00 denotes the listed standard 1,000 pieces per reel. Confirm the packaging suffix when ordering. The final comparison should identify frequency, output, supply, control voltage, APR, and package for each proposed part. Recheck the guarantee wording if the manufacturer changes.