After an OCXO replacement, a closed-loop frequency controller repeatedly corrects in the same direction until its code saturates. First verify control polarity. Higher control voltage can raise or lower frequency, and an inverting amplifier can reverse the overall code-to-frequency direction. Equal tuning widths do not establish equal polarity.
Check both signs in open loop
Set a safe control value in open loop and wait for warm-up. Near center, apply a small known increase in control code. Measure voltage change at the control pin and then frequency change. This identifies code-to-voltage and voltage-to-frequency signs. For example, if increasing code lowers the pin by 20 mV but raises frequency by 2 Hz, voltage-to-frequency slope is negative while code-to-frequency slope is positive.
Check the firmware's error convention. If error is measured minus target, a positive error should produce a correction that lowers actual frequency. Apply a small test correction and check that it reduces the error before restoring ordinary loop gain. Repeated overshoot after a correctly directed correction calls for checking gain and delay. It differs from a simple sign error.
Save the original control value before testing and avoid returning to automatic control with a saturated integrator. Repair acceptance should specify tuning polarity as well as center voltage and range. Use one error convention in schematics and firmware. Where repair variants share software, bind the direction to the actual assembly revision.SiTime AN10020 guidance on frequency-change polarity