Multiplying a 20 MHz VCXO's nominal frequency by 1% gives 200 kHz, but that does not describe its linearity. VCXO linearity generally expresses the largest deviation from a reference voltage-to-frequency line, normalized to tuning span. Check the manufacturer's line definition and whether it uses a one-sided or full span.
Use data that can be recalculated
Suppose the legal control range produces a total 4 kHz tuning span. One percent of full span is 40 Hz. A point 35 Hz from the specified line is 0.875% of span. This residual serves a different purpose from absolute error relative to 20 MHz. Correct endpoints do not guarantee a straight middle.
Record actual control-pin voltage and settled frequency at both endpoints, the midpoint and intermediate points. Confirm whether the reference line connects endpoints or uses a specified fit, then calculate signed residuals for every point. Different definitions can produce different maxima from the same data. A typical curve without a line definition is not a rejection criterion.
For open-loop calibration with one slope and intercept, the largest residual indicates remaining static error. If firmware supports a lookup table, also verify it across temperature. Retain the total span, voltage of the maximum residual and normalized ratio for future revisions.SiTime AN10020 linearity and tuning curve