A slow voltage sweep confirms static tuning range, but the VCXO can still lag rapid loop corrections. Apply a small AC signal around a normal bias and measure how frequency deviation amplitude changes as modulation frequency increases.
Use the low-frequency response as a reference
Hold supply, load, DC bias and small-signal amplitude fixed. Record frequency deviation amplitude at a sufficiently low modulation frequency and then increase the modulation rate in steps. If 100 Hz deviation falls to about 70.7 Hz, its amplitude response is down roughly 3 dB. Plot modulation rate against the frequency response to control voltage. Output carrier bandwidth does not answer how fast the control loop can follow.
If the control line includes long routing, a resistor and a filter capacitor, measure modulation at the device pin. If the generator amplitude is constant but pin amplitude drops with frequency, the observed corner includes external circuitry. Avoid reaching the control limits, because clipping makes frequency deviation nonlinear with input amplitude.
Specify required control bandwidth, permissible gain change and operating bias together. If phase lag affects stability, obtain phase response or verify the real closed loop. Two VCXOs that pass a static sweep can differ dynamically. Retain modulation frequencies and response ratios with a capture of the waveform at the control pin.SiTime AN10020 definition of control voltage bandwidth