The reference originally feeds one receiver, and the system now needs a second instrument in parallel. The Vectron OX-5021-EAE-1080-20M000 specification gives ±10 ppb frequency change for a ±5% static load variation from the specified value. Calculate the load change before using that limit for two instruments. It limits frequency shift under the stated conditions and does not separately guarantee far-end amplitude or waveform.
Calculate the load using the actual receiver settings
The ideal parallel combination of two 50 Ω resistive terminations is 25 Ω, half the value of one 50 Ω termination and well beyond a ±5% window. Confirm input impedance, termination switches, cables and adapters on both instruments. This example shows scale. Check the exact oscillator model for its allowable load. A high-impedance input still has capacitance and cable effects at high frequency.
Compare distribution schemes that meet the receiver requirements
Have engineering compare the input loads and output requirements for direct parallel connection, an isolated distribution buffer or another supported arrangement. Measure source frequency shift and amplitude at both receivers. Record how one output changes when the other load is added or removed. If inputs have switchable termination, include accidental selection during operation in the instructions.
Keep the manufacturer's load condition, actual system load and distribution costs in the comparison. Apply the specified frequency limit only when the real load lies within the verified range. Document the electrical requirements of adding a second instrument in the interface specification. Microchip Vectron OX-5021 part-specific specification