Two pilot revisions still need clock-tree changes, and purchasing wants to reuse the same 5P49V6965 samples. The VersaClock 6E programming guide distinguishes volatile RAM from one-time programmable memory. OTP bits can only change from the unprogrammed one to zero. User tables load settings at power-up. Repeated experimentation and permanent programming need separate procedures. Reconnecting the configuration program does not make a programmed table erasable.
Get the design working with reversible settings first
Save candidate frequency settings, output levels, board reference, and loads. For each trial, record whether the changes went into volatile registers or the nonvolatile user area, and identify the power-cycle outcome. If using multiple presets, record the hardware selection. It selects an existing configuration and does not restore programmed bits to the factory state. Check the history of an old evaluation board instead of assuming it is blank from appearance.
Reserve a separate fresh sample for permanent programming
After selecting the settings, have a second person check the board revision and actual configuration file, and program a dedicated confirmation sample according to the manufacturer's steps. Remove the programmer and debug cable, cold-start on system power, and check each default output frequency and interface. Dependence on a debug computer to reload settings means production startup has not yet been verified. Save programming and readback records and identify factory trim areas.
Quote reusable development samples and preconfigured production units separately. If the supplier programs the devices, agree on the configuration revision, identification method, and first-piece confirmation. Even if the base IC stays the same after a redesign, assign a traceable new configuration number. VersaClock 6E register and programming guide