Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

A W5500 test lists a 50 MHz host. Does the network board need a 25 MHz or 50 MHz crystal?

A W5500 test record lists a 50 MHz controller, a 25 MHz SPI clock, and a 25 MHz crystal on the board. The project handover only says 50M clock. That description can send purchasing to the wrong reference designator. Map every frequency to its physical signal before determining which clock needs a passive crystal, an active oscillator, or an existing circuit output.

Match the test setup to the board

WIZnet's W5500 SPI performance page includes a test with a 50 MHz host clock and a 25 MHz maximum SPI clock. Those are conditions of the test. The W5500 datasheet separately identifies XI/CLKIN as an external 25 MHz crystal or suitable single-ended clock input. The reference design shows a crystal and supporting components between XI and XO. The datasheet directs users to leave XO open when driving XI/CLKIN with an external clock. One 25 MHz number describes the host's serial transfers. The other describes the local W5500 reference.

A procurement request should include the actual designator. Trace a position such as Y2 to XI and XO or identify the separate active output. If 50 MHz is generated by the MCU clock tree, the repair BOM may have no 50 MHz component. Check the host datasheet and firmware for its own reference. A system frequency reported by software is not the external crystal frequency. Use the schematic for each board version instead of the controller speed from a test system.

Use timing arithmetic to distinguish the nodes

A 50 MHz period is 20 ns and a 25 MHz period is 40 ns. An ideal divide-by-two could produce 25 MHz from 50 MHz. The serial clock and internal reference still have different roles. An eight-bit transfer at 25 MHz takes about 320 ns before select and inter-frame overhead. SCLK may stop between accesses. Check the local reference against its operating requirements. Seeing 40 ns bursts on both test points does not establish interchangeability or continuity.

When a quote states 25 MHz ±20 ppm, establish which part and method it describes. That example represents ±500 Hz about 25 MHz. For the passive crystal, specify load, drive, and temperature. For an active oscillator, specify electrical output, load, and continuity. Counting an SPI burst does not validate the W5500 reference against ±500 Hz. The figure illustrates the calculation and is not a WIZnet limit.

Qualify the active version as a circuit change

For the passive build, collect frequency, load capacitance, ESR, drive, temperature, and geometry. The reference circuit's fitted capacitors and the crystal's specified effective load are different quantities. Use the intended part and actual network. If the supplier proposes an active 25 MHz oscillator, verify its output against the input requirements. Review supply, bypass, enable, and removal of the original oscillator loop. Identify the board revisions approved to use it. Physical fit through an adapter does not qualify it.

On the first article, capture SCLK during an actual host transaction, then verify the local reference at an approved point. If the MCU clocks an access and sees no response, check chip select, bus mode, reset, and the W5500 reference. A working reference and broken link call for other checks. Retain a known-good board's trigger, register access, and link evidence to show what the crystal change actually resolved.

If the field team supplies a prototype photo, distinguish the module from its carrier. A clock fitted inside a purchased module can be included in the module code. For a bare W5500, the BOM needs the actual crystal, capacitors, and any bias or link resistors. Ask whether a quote for a board with a crystal means a populated module or a separate clock packaged with the controller. Retain revisions and placement evidence. Give any new contract manufacturer the reference designator and document revision, not just a generic quantity list.

For a passive-to-active change, compare the same failure scenario on both builds. Execute repeatable register reads and link establishment on the original, then hold host, cabling, and network settings constant for the new build. Record power order, any extra reset, and clock availability. If the host can remain powered while the network circuit is off, verify whether the oscillator remains driven and whether the system resumes as designed. Keep practical checks in the line test and the fuller evidence in the approval record.

Once the external oscillator is approved, identify its supply and control function in the material record. A precise description makes it easier to match the same device in later builds and tests.

Put each frequency on the correct record

Use separate fields for the host clock, SPI rate, and W5500 reference. Order the actual factory number for the crystal position. An external oscillator brings its own circuit and acceptance records. Where a customer supplies only an older test report, have hardware or service trace the physical board before choosing material. A signed quote should identify the device category and the output or load conditions. Production can then identify the correct passive or approved active reference at the intended position.