A board uses a zero-delay buffer to distribute one oscillator reference to several modules. The buffer locks, but the oscilloscope still shows an edge offset at the farthest module. Identify the ports that define zero delay. In a buffer with external feedback, the loop aligns the feedback input with the reference input. The individual paths from the buffer to the receivers still contribute delay. Decide whether the alignment target is a device pin or the point where the board actually samples.
A PLL can compensate propagation along its feedback path
A typical arrangement connects a feedback output to a feedback input. The PLL adjusts its outputs based on phase difference between reference and feedback at the comparison point. With extra delay in the feedback route, the loop advances the output so the edge arrives at the feedback pin near the reference edge. Renesas's zero-delay timing note compares the load route with the feedback route. Similar propagation delays bring the load edge close to the reference. Longer load paths still lag. If the feedback path is longer, a load's edge can appear to lead once locked to repeated cycles.
This describes phase on a periodic signal. Each edge still travels along the physical traces. The PLL uses the repeating period to adjust later edges. It cannot deliver an arbitrary new event before it occurs. Test dynamic behavior on clock restart, a sudden edge shift, and recovery before lock. Check feedback path limits and which cycle is being compared for a long route. Average frequency and a lock signal do not establish edge timing or valid startup pulses at each load.
The Renesas approximation subtracts feedback-path delay from load-path delay, then includes static phase offset and output skew. The part's data sheet may specify different measurement thresholds, supplies, and loads for those terms. If feedback and receiver thresholds differ, a slow edge can cross them at different times. Match electrical delay as well as geometric length, then check the real edges. A trace length requirement alone cannot establish offset at the load.
Worked example: Three paths and the sign of the phase offset
Suppose the feedback path takes 420 ps, the near load 300 ps, and the far load 600 ps. Ignoring static offset and buffer skew, the near load leads the reference by 120 ps and the far one lags by 180 ps. The two load edges differ by 300 ps. With a hypothetical ±150 ps budget against the reference at each receiver, the near load passes and the far one fails. Adjusting feedback to 450 ps puts both at the boundary of the ideal calculation. Allow for actual device offset, waveform shape, and temperature, because an ideal result on the limit leaves no margin for them.
If a third module adds a connector and daughtercard, its route may be longer again. Extending feedback to that receiver also shifts the phase of every other output. Put all destinations in a table, with each segment's delay and the same feedback reference. If the far channel and near channel must align, routing changes or a device with per-channel adjustment may be more effective than increasing feedback length. Check the data sheet for adjustment capability and range.
Measure the reference, feedback input, and load on a prototype. With consistent thresholds and deskewed probes, first check residual reference-to-feedback offset after lock. Compare each load with the reference and record the direction of the change as route and load vary. If a daughtercard causes a larger offset than predicted, check termination, input buffer, and connector. Use low-loading measurement where a probe can alter feedback.
Specify ordering and acceptance at the same time
When comparing zero-delay parts, identify internal or external feedback, supported divider ratios and interfaces, and the point at which zero delay is specified. With internal feedback, include PCB and connector delay in the system review. For external feedback, provide its schematic and termination to layout and test. Document reference, alignment point, thresholds, allowed phase offset, and definition of settled lock. That makes the result reusable when a board changes or a module is added.
A measurement reference cable between modules has its own delay. If apparent skew changes with the fixture, calibrate the fixture before modifying feedback. Save actual load waveforms alongside any overlay at the buffer outputs.
If feedback uses a different termination from ordinary outputs, check the applicable reference voltage and swing. Equal propagation times with different load capacitances can yield different edge slopes. Record whether timings use each signal's 50% crossing or the actual receiver threshold before comparing them.