Ultrasonic welding near a crystal: why cleaning validation is not enough
Original diagram (Chinese labels). Illustration from the original MERLIN guide. See the article for calculation assumptions and applicability. Manufacturer reference ↗

Manufacturer guidance

Under Mounting, KDS recommends avoiding ultrasonic welding in assembly or processing. Excess vibration can reach the crystal, degrade its characteristics or prevent oscillation. This guidance is about the process and provides no universal limit derivable from frequency, package size, or previous cleaning results.

Review the mechanical path

Cleaning, welding and other vibration processes can couple energy differently. Map the connection from the weld to the crystal through the PCB, fixture, housing and other parts. Distance alone cannot establish safety.

Keep the weld location, assembly sequence, fixture constraints, equipment and process records. Do not infer permissible power, time, pressure or other thresholds from a package drawing. A device with no visible cracks can still have changed electrical characteristics.

Verify the new process

Under conditions agreed by the project owner, compare function, start-up and required electrical characteristics before and after processing. Retain unprocessed controls. Set the sample size and acceptance criteria in the project specification.

Limit findings to the recorded station, process and hardware revision. Reassess if the crystal, PCB, fixture or assembly sequence changes.

CheckRecordScope
ProcessCleaning and welding separatelyValidation cannot be transferred automatically
Mechanical pathCrystal, PCB, fixture and housingDistance alone is insufficient
Process recordEquipment, settings, station and sequenceUse documented limits
ValidationBefore/after results and untreated controlsApplies to the tested configuration

References and scope

Manufacturer documentation

MERLIN used AI assistance to compile this technical guide. Numerical examples are hypothetical unless identified as manufacturer specifications. They are not sample measurements, compatibility guarantees, or statements of availability.

Related selection resources

Quartz crystal packages and selection resources