Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Why should an RFQ for a CC1352P 48 MHz passive crystal include motional inductance?

Two quotes for a CC1352P radio board both say surface-mount 48 MHz, 7 pF and 60 Ω maximum ESR. Before choosing either 48 MHz passive crystal, check the motional inductance requirement in the Texas Instruments clock table. Distributor filters often omit this parameter. Ask each vendor for motional inductance or an equivalent crystal model for the exact ordering code, with the measurement conditions and limits. Standard frequency and load checks alone cannot show whether the offered part meets the radio MCU's oscillator requirements.

Calculate the inductance limit at the crystal's rated load

The CC1352P crystal table requires motional inductance below three times ten to the minus twenty-fifth, divided by load capacitance squared. Enter capacitance in farads to obtain henries. With 7 pF, the result is about 0.00612 H, or 6.12 mH. A crystal guaranteed at 5.5 mH maximum can advance on this item. A second candidate with 7 mH maximum is outside the limit and may need to be replaced. The inequality is strict. Keep enough significant digits to avoid rounding a borderline part into compliance.

Apply the same formula to 6 pF and the result is approximately 8.33 mH. At 9 pF the result is about 3.70 mH. Changing from a 7 pF to a 9 pF 48 MHz passive crystal changes the maximum in the approval record. The load is squared, so the former limit cannot carry over. Even parts from the same family need data for their exact suffixes. Engineering should confirm the combination of on-chip capacitor settings, parasitics and any physically installed capacitors.

Motional inductance belongs to the motional branch of the crystal equivalent circuit. If the vendor enters case shunt capacitance or a physical component rating in that field, return to the equivalent-circuit definition. A receiving report should give the original unit, part number, test frequency and drive, and say whether the number is typical or guaranteed. A typical 5 mH result at room temperature can inform sampling priority. For a design with a hard limit, get the guaranteed value or document the conditions used for approval. If the vendor changes its crystal element later, both parties will have the original criterion.

A vendor may provide the series-resonant frequency and motional capacitance. For a single motional branch, inductance is one divided by angular frequency squared and then by motional capacitance. Suppose measured series resonance is near 48 MHz and motional capacitance is 2 fF. This gives about 5.50 mH. It falls below the example limit at 7 pF, but ask whether the capacitance is typical, a lower limit or actual lot data. Inductance varies inversely with capacitance, so a maximum capacitance generally cannot establish a maximum inductance. Use frequency from the same equivalent model. A nominal loaded frequency under a different test condition is not an exact series-resonance measurement.

The ESR limit follows the rated load too

The data sheet has two resistance bands. Above 6 pF and up to 9 pF, the limit is 60 Ω. Above 5 pF and up to 6 pF, it gives 80 Ω. A 6 pF crystal falls in the latter band. A 6 pF candidate guaranteed at 75 Ω may meet this line. A same-size 7 pF candidate with the same guarantee is above the applicable 60 Ω limit. Check load and resistance together on the order and read the inequalities where a part sits on the boundary. Compliant inductance cannot make an excessive ESR acceptable.

TI integrates adjustable load capacitance. Its typical 7 pF includes parasitics on the reference design. It does not correspond to installing two 7 pF external capacitors by default. Record the reference design, production board revision, populated or unpopulated capacitor positions, and the customer-configuration setting. Applicable errata may change whether external load capacitors are needed for some compliance cases. Check the exact silicon and circumstances. Qualify the guaranteed crystal on the real board and keep any footprint or solder-mask change visible so changed board parasitics are not attributed to the part alone.

Request the test report behind each stated limit in the first quote. If two reports for the same full ordering code use different conditions, record their temperatures, drive and sample lots and ask which report represents the shipping guarantee.

Connect the supplier's data to first-article acceptance

A 48 MHz active TCXO is a separate clock input option on this MCU. TI gives separate receiver conditions for clipped-sine and directly coupled CMOS sources. If a supplier quotes an active part in place of a crystal, route it through the separate material approval. Its output, supply and receiver interface need their own validation. A 48 MHz oscillator output plot cannot supply the passive crystal equivalent-circuit data. On the crystal route, save the ESR and motional inductance limits before board startup and frequency testing.

Use an approved test point and method. TI warns that probing or otherwise stopping the crystal while the on-chip DC/DC converter is enabled can permanently damage the device. Check the power architecture and manufacturer procedure before attaching a probe. On first articles, record the low operating rail, hot and cold startup, actual selected source and measured frequency. Compare startup and failures when the lot changes. Link the results to the crystal specification, lot, board and configuration. Even if every trial unit starts at room temperature, an offer without the required limits should remain an engineering sample.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.