An upstream clock module goes to sleep and its oscillator output is disabled. A differential buffer remains powered and downstream logic is expected to wait. Check whether the buffer sees a driven level, nearly zero differential voltage, or floating inputs. None produces a normal steady clock, and each can respond differently to interference and restart. When selecting a buffer and its surrounding circuit, check both the no-input behavior and how downstream logic recognizes a missing clock.
Stopping the source changes what the buffer sees
Some oscillators drive a fixed low level when disabled. Others switch to high impedance. For a differential source, check the bias on both pins when disabled. If the pair is AC-coupled, the receiver does not retain the source's DC output voltages. After the capacitor charges settle, the receiver-side bias sets the two pins. A termination across the pair also pulls the two voltages together. With a comparator input that has no fail-safe behavior, noise near the differential switching point may cross the threshold repeatedly. The downstream logic can count those crossings as clock edges.
Input hysteresis creates separate thresholds for the two transitions. Once the receiver decides on one state, the voltage must cross the other threshold to switch back. Noise below that threshold is less likely to produce repeated transitions. Other devices detect a missing clock and disable outputs according to hardware or register settings. An AC-coupled square wave produces a transient when it stops. Disabling the source, disconnecting the cable, and removing power can create different transients. Check pulses at the transitions separately from the quiescent output behavior.
TI's LMK1D210x section 8.3.1 describes two separate capabilities. The family allows signals at its inputs before it is powered, within the absolute maximum ratings. It also uses input hysteresis to suppress random oscillation when the input is absent, and permits unused inputs to float. The first statement addresses power sequencing. The second addresses behavior with no input signal. A different data sheet's “fail-safe” label establishes both only if its conditions say so. Permission to leave a pin unused also does not establish a guaranteed output polarity with a long unterminated cable picking up noise.
Reproduce three ways of losing the clock
Suppose two modules share a clock through a pair of AC-coupling capacitors. The downstream circuit counts one valid output edge at a time. Try three actions that the prototype can safely support. Disable the oscillator using its pin while leaving the buffer powered. Disconnect the source module while leaving the interconnect at the buffer. Remove upstream power as it would be removed in the product, keeping the receiver supply unchanged. Record the shutdown action, differential waveform at the buffer input, output, and downstream count together.
Use a short window immediately after shutdown to see whether the last pulse is shortened or an extra transition occurs. Use a longer window to watch for stray pulses after things settle. On restart, capture the first valid clocks and see whether a short initial pulse is missed or a phase change causes a premature count. Keep probe positions and loads fixed and use the board's intended differential terminations. If a count changes and the scope did not capture the event, use the count change to trigger a longer acquisition when feasible.
For example, suppose disabling the oscillator and removing upstream power cause no counts in the stable interval, but disconnecting the module occasionally does. Inspect the extra floating interconnect, disconnect operation, and nearby active signals. Passing the other two tests does not establish acceptance for the unplugged case. If all three show one extra event at shutdown and remain stable in the long window, check enable timing against the clock edge and determine when downstream logic begins waiting. That separates pickup in the idle period from a single transition during shutdown.
Decide where the system will recognize a missing clock
A quiet buffer output is one requirement when a processor or counter must stay in a defined state during sleep. Set how downstream logic will detect a missing clock, mask the input through an independent valid signal, or stay in reset until it can resume. Specify the first acceptable pulse width and timing, and how long the system can wait after a cable disconnect. A missing-clock timeout needs a timebase that continues running after the monitored clock stops.
When comparing pin-compatible buffers, ask for behavior with floating, shorted, and open inputs as appropriate, and check the disabled state, enable timing, and power-up limits. If the data sheet guarantees suppression of oscillation and the project additionally requires a defined output level, choose a configuration that explicitly provides that level or implement downstream masking. Keep the actual disconnect and clock-stop actions in the approval record so they can be repeated after oscillator or sleep-mode changes.
If a downstream reset is available, test with and without masking and inspect the buffer output even if the masked counter stays unchanged. An extra pulse observed at the buffer remains part of its measured behavior, even when the receiver ignores it. Keep that result separate from the system's ability to tolerate it.