A mainboard and acquisition board use isolated supplies. To share one oscillator, a designer feeds the clock through a spare digital isolator channel. A 100 Mbps headline rating looks like twice the 50 MHz clock. The useful quantities are the shortest high and low intervals the channel has to transmit. At 50 MHz with 50% duty cycle each interval lasts only 10 ns. Duty-cycle tolerance and pulse shortening through the isolator can reduce that further.
Convert the data rate to an interval
If a 100 Mbps test sends one level per bit time, each bit lasts 10 ns. An alternating one-zero pattern needs two bits to repeat, corresponding to a 50 MHz square wave. ADI's isolated SPI note uses the distinction between clock cycles and data bits, since the clock changes twice per period and data need not change every bit. Find the minimum input pulse width and applicable supply and load conditions in the actual part's switching table. Headline rates may use different patterns, test points, and edge conditions.
Also examine the output timing. Data sheets usually give propagation delay separately for rising and falling edges. A difference in delays lengthens or shortens the high interval and does the opposite to the low interval. In steady operation the measured output frequency can still match, even when the receiver misses the shorter state. The TI ISO774x data sheet gives the absolute difference of the two delays as pulse-width distortion and lists switching characteristics by supply condition. This value bounds time a high or low pulse can lose. Either propagation delay alone describes something different.
Whether the clock is a local reference or travels with data and a sync signal changes the timing review. A fixed propagation delay largely shifts the phase of a standalone reference. With parallel clock and data, include channel delay differences and actual PCB routes. If data comes back across the barrier and is sampled by the original clock, include both travel directions. Passing the one-way clock pulse check below is only one step toward system timing approval.
A worked example for 50 MHz and 40 MHz
Suppose the oscillator guarantees 45% to 55% duty cycle on this branch. A 50 MHz period is 20 ns, so the shorter interval is 9 ns. If a hypothetical isolator requires a minimum 10 ns input pulse, this input is outside the guarantee even if the part is advertised as 100 Mbps. Ideal 50% duty cycle gives exactly 10 ns and still needs review for frequency tolerance, supply, and the waveform measurement definitions.
Now use the same hypothetical parts at 40 MHz. The period is 25 ns and 45% is 11.25 ns, leaving 1.25 ns above the 10 ns minimum. If maximum pulse-width distortion is 3 ns, the shortest output interval is estimated as 11.25 − 3 = 8.25 ns before PCB and threshold effects. A receiver requiring 9 ns is still not guaranteed to work. With the same assumptions, the input must provide at least 12 ns to leave 9 ns after distortion. Dividing 45% by 12 ns gives an ideal limit of about 37.5 MHz before allowing for board effects or clock tolerances.
Probe at the isolator input and the real receiver input. At the target frequency, use an adjustable source or a characterized oscillator and check the worst duty cycle. Log the short high and low intervals at both ends, together with the thresholds used. Repeat at the actual supply limits and load and compare which pulse shortens. Use the correct local reference at each measurement point. When insulation must be preserved, use measurement equipment and connections rated for the conditions so an ordinary grounded probe clip does not bridge the barrier.
Decide whether to change the part or the clock
If the minimum pulse widths cannot be met on both sides, reduce frequency, choose a channel with less distortion, or generate the destination clock locally. A local source changes frequency error or synchronization between the domains, so it depends on the architecture. If a common long-term reference is essential, get an appropriate isolator and its detailed timing data. Attach the minimum pulse measurements to the approval even when the frequency counter reports 50 MHz.
For purchasing, record both supply voltages, exact ordering code, operating temperature, and direction through the isolation channel. List minimum input high and low times, maximum pulse-width distortion, and the receiver's limits separately. If the acquisition board starts and stops, check the first usable clock after the supplies have settled. This shows whether the present channel is suitable and why a lower frequency might still miss edges.
References
- Analog Devices AN-1478, Isolated SPI Bus for Distinct System Requirements, data rate, clock period, and pulse-width distortion
- Texas Instruments ISO774x, Switching Characteristics and Parameter Measurement Information
- Analog Devices CN0335, isolator data rate, clock frequency, and round-trip propagation delay