A clock board uses a switching preregulator followed by a low-noise linear regulator just for the oscillator. Spurs near the output shrink with a fully charged battery. Near the end of discharge a multimeter still shows normal oscillator supply, but the spectrum shows the old sidebands again. Measure the input-to-output headroom of the linear regulator under that condition and check its rejection there. The typical value on the first page of a data sheet may correspond to another operating point.
Ripple rejection can degrade while the DC output remains in range
A low-dropout regulator, or LDO, uses an internal amplifier and pass device to regulate its output. With enough input-to-output headroom, the loop can respond to input disturbances. Loop gain may drop as headroom shrinks, passing more ripple, even while the average output stays within range. Read power-supply rejection ratio with its measurement conditions. Dropout is the minimum input-to-output difference needed to maintain regulation under specified conditions. Headroom is the actual difference in the circuit. Checking maximum dropout is the first step. Also check the rejection needed in the relevant frequency band.
ADI's LDO operational corners article compares rejection at several headrooms for an ADM7160 at a fixed 200 mA load. Its curves vary with frequency and headroom. A different operating point on the same part can give very different typical rejection. Load current changes the operating state of the pass device. Clocks and buffers can draw different currents in different output modes, so compare at actual current, output capacitance, and temperature. A typical curve still needs validation at production limits.
Read intrinsic output noise separately. It is commonly given as RMS voltage over a stated band, while rejection of input ripple is given in decibels versus frequency. A regulator with very low intrinsic noise can perform well with clean input and adequate headroom, yet pass one preregulator ripple line on a board with little headroom. Determine whether the spur follows the input ripple frequency and whether it responds to changes in headroom.
A worked ripple and headroom budget
Assume 10 mV peak-to-peak input ripple. At its main frequency, assume 40 dB rejection under condition A and 20 dB under condition B. The voltage ratios are 100 and 10. The transmitted component is approximately 0.1 mV peak-to-peak in A and 1 mV in B. The average output can remain in the oscillator's rated range in both cases. If the oscillator is susceptible to supply modulation there, measure the output spur. These figures cannot predict its level in decibels.
Suppose the preregulator averages 2.05 V with ripple troughs of 2.00 V and the LDO is set to 1.8 V. Average headroom is 250 mV and trough headroom is 200 mV. If a load step takes another 40 mV from the input, only 160 mV remains temporarily. Compare steady, periodic, and transient cases to the LDO's dropout and typical rejection curves. Include PCB and connector voltage drops and battery temperature, rather than estimating pin headroom from open-circuit battery voltage.
Use an adjustable input to reproduce full and nearly empty battery conditions while holding the downstream load and oscillator constant. Record LDO input, output, local oscillator supply, and the clock with the same probes. Annotate load transitions. If ripple and sidebands change with headroom, investigate that path. If the sideband ignores headroom but follows another interface's transmit activity, revisit return paths and coupling. Where the manufacturer allows, compare controlled disturbance injection with a separate low-ripple supply to measure oscillator sensitivity.
What belongs in the power-supply approval
Review minimum preregulator output, LDO headroom, filter capacitors, and worst-case oscillator current together. A higher preregulator voltage gives more headroom and increases dissipation, especially on a shared rail. A lower-dropout alternate still needs checks at temperature limits, with the actual series resistance and stable output load network. Document the specific failing condition, such as insufficient headroom during one load step, instead of replacing parts solely on a low-noise label.
First check oscillator supply over the worst input range, then check limits at ripple-related frequencies and verify startup. Keep the low-battery, maximum-load case in the test record. It is then possible to reproduce a field difference without discarding the full-battery measurements.
Check the oscillator decoupling ground. An external supply lead may change the ground loop at the same time as it increases headroom. Change the preregulator setting with connections fixed first, then use the alternate supply as another comparison. Record the load and the regulator's thermal condition.
Include wakeup if it increases clock distribution load. An average can remain in range while a trough lasting tens of microseconds degrades rejection. Exercise wakeup and load switching near the lower battery limit and identify trigger time and supply node on the capture.