Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Same crystal frequency and ESR: Can higher C0 make startup harder?

Two candidate crystals appear to match in frequency, package, load capacitance, and equivalent series resistance. Another data sheet row, marked static or shunt capacitance and denoted C0, sometimes lists only a maximum. It deserves attention when the oscillator amplifier on the original PCB has little margin. In STMicroelectronics' symmetrical Pierce approximation, a crystal with higher C0 calls for a higher critical transconductance under the same startup and sustaining conditions. Estimate the difference first, then evaluate it with representative boards.

Keep three capacitance values separate

A crystal's electrical equivalent circuit uses a series inductor, capacitor, and resistor to represent its mechanical resonance. C0 spans that branch and mainly represents static capacitance from the electrodes and package. The crystal symbol may have only two working connections, but C0 is already inside the device. The external capacitors and stray capacitances on the PCB provide the load capacitance CL seen from the crystal terminals. Record the value of each external capacitor, the crystal's rated CL, and C0 in separate columns.

CL defines the external condition under which the manufacturer trims the crystal to its specified frequency. C0 is part of the oscillator-loop analysis. Equivalent series resistance, ESR, represents loss. The amplifier must supply enough gain for a small disturbance to grow into sustained oscillation. Lower ESR generally makes the loss easier to overcome. Two parts can have the same ESR and need different amplifier capability if C0 differs. First make sure you are comparing like values, such as maximum with maximum rather than typical with maximum.

ST's AN2867 section 3.4 estimates critical transconductance for equal external load capacitors and an actual load matching the specification. Multiply ESR by four, by angular frequency squared, and by the square of C0 + CL. Transconductance expresses the change in output current per change in input voltage, in amperes per volt. When comparing two crystals at the same frequency under these assumptions, the capacitance sum is squared. A difference of a few picofarads on the data sheet can therefore matter.

Put numbers on the difference

Take two hypothetical 16 MHz crystals with the same 70 Ω maximum ESR and 8 pF rated CL. Under equivalent specifications, one has C0 = 2 pF and the other 4 pF. The sums are 10 pF and 12 pF. The second part's critical transconductance is (12 ÷ 10)² = 1.44 times that of the first. At 16 MHz the estimates are about 0.283 and 0.407 mA/V, respectively.

If a hypothetical amplifier provides 1.5 mA/V under the comparison conditions, the ratios are about 5.3 and 3.7. The rest of the board can stay the same and the estimated startup margin can still differ. These are illustrative device and amplifier values. The real target ratio depends on the microcontroller manufacturer's method and the selected drive setting. Temperature, supply voltage, and internal parameters can change the available transconductance. The sample ratios are not acceptance limits for any particular chip.

If the crystal data sheet specifies a maximum C0, use that upper limit for a preliminary worst-case calculation. Comparing one part's typical value with the other's maximum does not support a strong conclusion about lot behavior. After comparing both parts using supported limits and the same ESR definition, keep the prototype check. Some microcontroller vendors publish a permitted load and ESR range or a list of validated crystals. Follow the supplied method and do not fill in an unpublished amplifier transconductance.

What to put in the substitution record

Put full part numbers, source document revisions, CL, ESR, C0, temperature range, and the type of limit in one table. Link the microcontroller's oscillator type, minimum supply, drive setting, and calculation method to the same verification record when available. If the data sheet lists C0 only for a family, ask for the electrical specification for the exact ordering code. Convert all values to the same units before calculating. A picofarad-to-farad conversion error is amplified by the squared capacitance term.

Compare candidates on boards using the original crystal pads, load capacitors, and drive setting. Use the same power-off wait, supply ramp, and temperature to check startup and continuous operation. If low supply or temperature extremes cause problems, investigate with the microcontroller vendor's approved startup-margin method. A normal frequency after replacement establishes the result at that operating point. Checks at supply, lot, and temperature boundaries determine how far that result applies. Logging C0 helps prioritize the candidate that needs more startup work before samples arrive.

If the circuit differs from the assumptions, bring those differences into the review. Internal capacitors can change the balance and actual load, and a series drive-limiting resistor adds loop loss. Note when a measurement was taken. When the waveform first crosses a digital threshold it may not have reached steady-state drive. The frequency after startup cannot reveal how long the signal took to grow.

Keep a return-to-original control when evaluating the first boards. If the new crystal fails and the original also fails after reinstallation, inspect pads and residue from rework and use another board for comparison. If inspection records become available for both lots, first check whether static capacitance was measured the same way before extending approval to more parts.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.