A 3225 quartz crystal datasheet gives both load capacitance and shunt capacitance in pF. The board drawing has two capacitors to ground as well. The three entries belong in different places. Load capacitance describes a condition for the ordered frequency. Shunt capacitance is part of the crystal's equivalent circuit. The capacitors in the board bill of materials are the actual components that contribute to the load.
Find the distinction in an Epson specification
Epson's FA-238 configuration with ordering-code stem Q22FA23800133 specifies 16.000000 MHz and a load capacitance of 12 pF. The last two characters specify packaging. The electrical table lists a typical C0 of 0.93 pF and a separate motional capacitance C1 of 1.96 fF. On the approval sheet, enter 12 pF under rated load and 0.93 pF typical under shunt capacitance. Keep the two fitted capacitor values with the host chip and board revision. If the design requires a guaranteed upper limit for shunt capacitance, ask for it or agree on a lot qualification process. The table gives a typical value for this part. Epson FA-238 part specification, page 1, sections 2 and 5
A motional capacitance of 1.96 fF is 0.00196 pF. It sits in series with motional inductance and resistance in the model of the crystal's mechanical resonance. Shunt capacitance includes the capacitance formed by the electrodes and package. Draw it across the two crystal terminals, in parallel with the motional branch. The external load arises from the rest of the circuit, including external capacitors, the chosen internal capacitance setting and board parasitics. Verify the effective load on the board separately from the load specified for the crystal's nominal frequency. Epson crystal equivalent circuit and load frequency · Analog Devices explanation of holder capacitance
Inspect the two terminals in the simulation
Open the crystal symbol's subcircuit. If a capacitor representing C0 already bridges the terminals, that element represents the crystal's own shunt capacitance. Adding an identical capacitor outside the model changes what the circuit sees. A simplified model consisting of a series R1, L1 and C1 branch needs a shunt element to represent the same device. Label each component as part of the device, host or board and keep its source and unit in the model notes.
For a hypothetical loss comparison, use two crystals with 60 Ω motional resistance at the same 12 pF load. Let their shunt capacitances be 0.9 pF and 2.7 pF. Using the common load-resonance resistance approximation RL ≈ R1(1 + C0/CL)² gives 69.34 Ω and 90.04 Ω. Entering 1.8 pF in the first crystal's C0 field by counting its 0.9 pF twice gives 79.35 Ω. This illustrates an input error in the calculation. In a circuit model, track an added physical capacitor according to its actual connection. Check the real board using the loss or gain definitions in the host manufacturer's procedure. NDK oscillator evaluation and load-resonance resistance equation
If the host uses critical transconductance, use the equation and definitions given for that oscillator. Some equations already include shunt and load capacitance explicitly. Feeding an adjusted load-resonance resistance into a formula that calls for motional resistance can account for the loading effect twice. If the new part reaches the target frequency but takes longer to start, review the model inputs and the host oscillator settings along with the observed waveform. ST AN2867 on transconductance and oscillator safety factor
Ask what the fixture contributed to the reading
A lab can characterize the crystal's known terminals under agreed conditions or fit the equivalent model. Here is a simplified hypothetical example of fixture correction. Suppose 1 MHz is sufficiently far from the relevant resonances for the tested crystal and the open fixture has 1.13 µS of capacitive susceptance. With the device fitted, the reading is 7.04 µS. Subtracting the fixture contribution leaves 5.91 µS. With B = 2πfC, the two readings before and after correction imply about 1.12 pF and 0.94 pF. This assumes a simple parallel model and small residual terms. Use the fixture and calibration procedure required by the instrument and device manufacturer. Close to resonance, the measured response includes the motional branch.
Check the frequency, drive, terminal connection and fixture calibration on the report. A measurement taken on an assembled board might include the host input, PCB capacitance and probe. If a reported shift appears when the lab changes fixtures, remeasure the same unit under the agreed method before interpreting it as a device change.
Keep the two fields separate when approving a replacement
Check the device's rated load and enter the shunt capacitance only once in the model. Identify any shunt capacitance limits or other matching conditions in the host documentation. Compare parts on the same board configuration and record buffered frequency, startup across the required operating limits and crystal drive. For a host with automatic startup gain or programmable load, record the register readback so that the next lot can be tested with the same settings. Ask the supplier to state the complete ordering code, rated load, shunt capacitance with its evidence type, and motional resistance with its test definition. When the decision depends on how far a capacitor setting can move the frequency, see the MERLIN example on local pullability and trim range.