Why do two 26 MHz passive crystals show different ppm changes for the same capacitor step?

A production station trims a 24 MHz clock by stepping through a table of capacitor settings. Engineering fits a replacement crystal with the same size, frequency and rated load. The trim routine reaches its last setting, but the clock remains high. Check the initial frequency error and the frequency change per step separately. Purchasing can screen parts by their rated load. Engineering needs the two measurements to decide whether a particular part will trim on the existing board and firmware.

The two curves can differ around the same rated load

In the crystal equivalent circuit, C1 is the motional capacitance, C0 is the device shunt capacitance, and CL is the effective load presented across the crystal terminals by the circuit. With low loss and a motional capacitance much smaller than the total parallel capacitance, the fractional shift from series resonance is approximately C1 ÷ [2(C0 + CL)]. Increasing the load moves the frequency down towards series resonance. The approximate local slope is −10⁶ × C1 ÷ [2(C0 + CL)²] ppm/pF when capacitances in the expression are in pF. The slope generally gets shallower as load increases on the same curve.

Take two hypothetical parameter sets. Part A has 2.0 fF of motional capacitance, or 0.0020 pF, and 1.0 pF of shunt capacitance. Its model slope is about −8.26 ppm/pF near a load of 10 pF and −5.92 ppm/pF near 12 pF. Part B has 0.8 fF of motional capacitance and 1.5 pF of shunt capacitance. Its slope near 10 pF is about −3.02 ppm/pF. Both parts could be calibrated for 10 pF at the factory. Their tuning sensitivity will still depend on their individual parameters. The load on a PCB also depends on the host pins, layout and capacitor network. Measure around the setting the board actually uses. Epson formulas for load frequency, pulling range and sensitivity · NDK equivalent circuit and electrical characteristics

Use three readings to locate the accessible trim range

Characterize both parts at three nearby effective loads at the same buffered measurement point, temperature and counter reference. The following readings are a separate hypothetical bench example. Ppm is relative to 24,000,000 Hz. Each load value describes the effective circuit load. If the only known quantity is the register step, report ppm per setting and identify the settings. To compare slopes in ppm/pF across board revisions, document how the change in effective load was derived and how uncertain that estimate is.

Effective load at the crystalPart APart B
9.0 pF24,000,360 Hz (+15 ppm)24,000,240 Hz (+10 ppm)
10.0 pF24,000,144 Hz (+6 ppm)24,000,168 Hz (+7 ppm)
11.0 pF23,999,952 Hz (−2 ppm)24,000,108 Hz (+4.5 ppm)

Part A averages −9 ppm/pF from 9 to 10 pF and −8 ppm/pF from 10 to 11 pF. Part B averages −3 and −2.5 ppm/pF over the same intervals. For a ±2 ppm room-temperature target, the window is ±48 Hz. A reaches its lower edge at 11 pF. Use the slope between 10 and 11 pF to choose an intermediate setting to try. A further 0.75 pF would bring the +6 ppm error towards zero under linear interpolation. The actual reading decides whether that setting works. B remains 108 Hz high at the largest available load, surpassing the allowed positive error by 60 Hz. Evaluating it further would require additional usable load range, a different factory load specification or another approved calibration mechanism. A calculated point beyond the tested interval is a proposal for a test.

Account for step size as well as total adjustment

A shallow slope can consume the trim range. A steep slope moves the frequency more for each capacitor step and makes a fine adjustment harder. Suppose the working slope is −8 ppm/pF and available load settings are 0.25 pF apart. One step is about 2 ppm, and a target between two settings can leave up to 1 ppm of quantization error even with the closest setting. Assume the load can independently shift by ±0.10 pF after calibration, or about ±0.8 ppm, and allow 0.4 ppm for measurement. Summing the magnitudes gives 2.2 ppm, beyond the hypothetical ±2 ppm budget. Look for finer steps, better control of the remaining load variation, a more accurate reference or a revised product budget. Account for each source once. Load variation already removed by individual calibration belongs to a different part of the budget from variation that remains afterward.

Return to the baseline setting after the sweep. If it reads +6 ppm at the beginning and +8 ppm on the way back, a purported 2 ppm trim step is about the same size as the drift in that run. Check thermal equilibrium and the counter reference before accepting that slope. Measure startup at the useful trim settings under the required supply and temperature limits, and check crystal drive where it could change. A good frequency at room temperature cannot describe startup at the corners of the operating range.

Request evidence for the part over the relevant load interval

Collect the complete ordering code, rated load, shunt and motional capacitances, and frequency or pulling data across the planned load range. For sample data, retain the test fixture, temperature, drive, reference frequency and lot. Label typical measurements separately from guaranteed bounds. With typical figures alone, trial the samples and keep the production decision open until the range, resolution and variation have been demonstrated. The final approval can then identify the ordering code, board revision, allowable settings and the procedure used on the production station. For the source and measurement of shunt capacitance, see the MERLIN guide to crystal shunt capacitance and circuit load.