How to specify an acceptance window for spurious response suppression in a crystal

A 26 MHz crystal specification calls for at least 10 dB of spurious suppression. One supplier sends a sweep of the passive crystal. Another sends a spectrum captured from a powered oscillator. Before comparing either number with the requirement, identify what was measured and what the decibel value refers to. The next decisions are which resonances count, how the instrument resolves them and what engineering still needs to verify on the board.

Define the frequency interval and identify the main response

Quartz crystals have several mechanical modes. The circuit is intended to operate on a particular main mode. Nearby unwanted modes can be described by their frequencies and resonance resistances. Cardinal's quartz reference discusses characterizing them relative to the main mode by resistance ratio or a decibel expression. A passive sweep captures responses under the stated drive, load and fixture conditions. If output spectral spurs matter too, give that measurement its own node, loading, bandwidth and limits since other circuit elements affect it.

For an example centered on the nominal frequency, specify a sweep from 25.900000 to 26.100000 MHz with both endpoints included. Record the measured main resonance for each unit. In a project where the window is centered on the measured main resonance instead, explicitly state that rule. The same physical peak could land on different sides of a limit under the two definitions. Exclude the confirmed main response from the unwanted-mode criterion. If the agreement also excludes an interval around the main response, define its width and the retest method when neighboring responses cannot be separated.

Calculate the suppression using a 30 Ω main mode

Suppose the project uses a positive suppression quantity, 20 log10(Ri/R1), where Ri is the unwanted mode's fitted resonance resistance and R1 is the main mode's. A requirement of at least 10 dB means a resistance ratio of at least 3.162. With a 30 Ω main mode, each counted unwanted mode must have a resistance of at least about 94.87 Ω. Ask the lab to label the sign convention and reference. A weaker feature on a trace normalized to the main amplitude may instead be labeled with a negative value.

FrequencyResonance resistanceSuppression by resistance ratioDisposition in this example
25.920000 MHz150 Ω13.98 dBPass
26.000000 MHz30 ΩMain modeReference
26.045000 MHz90 Ω9.54 dBIn-window failure
26.100000 MHz105 Ω10.88 dBIncluded endpoint, pass
26.140000 MHz60 Ω6.02 dBOutside this window, reported separately

The 26.045000 MHz mode is the one that fails the stated limit. The more prominent mode at 26.140000 MHz is outside the acceptance interval. If it also presents a board-level risk, engineering can request an expanded window or a separate limit on a revised drawing. Record the contractual result and the reason for reviewing the wider sweep so the next supplier can reproduce both decisions.

Consider a simplified transmission measurement with a 50 Ω source, 50 Ω load and a series resistor in place of the crystal. Its voltage transmission relative to the through path is 100/(100 + resistance). Compared with the 30 Ω case, the 90 Ω case gives 20 log10(130/190), or about −3.30 dB. An actual quartz crystal has reactive terms and other modes, and the fixture may use different effective terminations. The example shows why the relative level on the screen depends on the measurement network. If the acceptance limit uses fitted resistance, retain the extraction method and data. If it uses transfer measurements, specify the fixture and reference that produce that result.

Check that the sweep can see a narrow response

Agree on the scan limits, point spacing, fixture calibration, sample temperature, drive and extraction method. A hypothetical peak with a width of about 300 Hz can fall between adjacent points 2 kHz apart. Confirm detection with a unit whose response has been characterized. Use a fine scan or an equivalent method that covers the region where narrow responses can occur. Zooming only on peaks already visible in a coarse scan cannot reveal those that were missed. Record settling time and bandwidth. Where two responses are close enough to merge, retain the complex measurement and resolve them with the agreed method before declaring a result.

Set a decision rule at the endpoints as well. A reading of 26.100050 MHz with expanded uncertainty ±200 Hz spans 26.099850 to 26.100250 MHz. The interval crosses the example's upper limit. One agreed procedure is to retain the candidate, retest using an improved reference or resolution, and then apply the approved acceptance rule. Use the same approach for resistance ratios close to the cutoff so laboratory and incoming inspection use compatible rules.

Verify the selected mode on the product board

With that crystal in the intended oscillator, power-cycle at the product voltage and temperature limits and inspect the first stable frequency at a known buffered output. Record whether changes of temperature or drive lead to a different mode. If a PLL or automatic clock switch is involved, record a reference-path measurement and the switching state. Purchasing can retain the unit's ordering code, lot, test window, response table and fixture revision. Engineering can retain board revision, load, drive and startup results. A supply approval can then say which unit-level and system-level requirements were actually checked.

See Cardinal’s Spurious Modes explanation and IEC 60444-9 for measurement of quartz crystal spurious resonances. If interference appears only as the board warms, see MERLIN’s narrow-temperature scan example.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.