An industrial crystal passes three temperature points. Why does it lose lock during warm-up?

Suppose a board with a 26 MHz quartz crystal passes frequency checks at −40 °C, 25 °C and 85 °C. The downstream PLL sometimes loses lock as the board warms through about 50 °C. Start by asking what happened to the reference just before the unlock. Then see whether the problem can be repeated at a stable temperature near the event or only during a ramp. A common timebase for the reference, lock indication and board temperature makes these questions easier to answer before changing parts.

Find the first event in the clock chain

Observe the crystal reference at a buffered output when the chip supports one and log the PLL status or output separately. Document the clock selected at the observation point during normal operation, after loss of lock and after any automatic fallback. A system clock output may switch to an internal oscillator after a reference problem. Its new frequency tells you what the system selected. A buffered output with a known divider can help track the external reference itself. Use a separate counter or timebase where practical, because a logger timed by the clock under test may lose time when that clock stops. Check the divider and the actual gate duration before comparing samples.

Retain frequency readings, supply voltage, PLL state and the measured temperature near the crystal with timestamps. Keep a distinct status for a counter timeout and preserve the last valid sample. Averaging across missing pulses can turn an interruption into an apparently smooth drift. If a reference change precedes unlock, inspect the crystal and front-end oscillator. If the reference stays steady, investigate the PLL supply, configuration and switching logic. An independent timebase or a repeated capture with another instrument can help rule out changes in the measurement chain.

A local disturbance can fit between ordinary test points

An AT-cut crystal can support several mechanical modes. As temperature varies, the main response and another mode may approach each other in frequency. Microchip AN588 describes how this can couple energy out of the main mode over a narrow temperature interval. The equivalent series resistance of that mode may rise and its frequency may deviate from the surrounding trend. The response can recover as temperature continues past the interaction. This is called an activity dip. Drive level can affect the result, so a board-level disturbance calls for an additional test on the individual crystal at agreed load and drive.

The following data are hypothetical. At 26 MHz, 1 ppm corresponds to 26 Hz. A product limit of ±20 ppm in the example is equivalent to ±520 Hz around nominal.

Board temperature near crystalReference errorOffset from nominalPLL state
25.0 °C+5.0 ppm+130 HzLocked
49.70 °C−7.5 ppm−195 HzLocked
49.95 °C−27.5 ppm−715 HzOffset captured before loss of lock
50.25 °C−8.0 ppm−208 HzLock recovered
85.0 °C+12.0 ppm+312 HzLocked

The valid reading at 49.95 °C is 195 Hz below the product limit. It is also 520 Hz below the recorded point at 49.70 °C. Those comparisons serve different purposes. Error against nominal determines whether the product met its frequency window. Deviation from the local curve helps identify a narrow disturbance. A pair of nearby readings is enough to illustrate the calculation. For formal acceptance, agree on the baseline or fitting method and retain the raw data with it. Ask the crystal manufacturer for the frequency and resistance traces from the same sweep to see whether both quantities change in the affected interval.

Set the sample interval using the actual board ramp

Run a broad scan to find the area of interest, then spend more time there. If board temperature is changing at 1.2 °C per minute, readings taken every 5 s are about 0.10 °C apart. A hypothetical 0.30 °C interval lasts about 15 s at that rate. There may be only a few readings across it, with still fewer inside a short dropout. Reduce the interval between valid readings or slow the ramp, then check that the frequency measurement still has the required resolution. Data transfer, waiting and the counter gate can all affect how far apart the timestamped results really are.

For example, if the clock is buffered with a divide-by-four setting, the observed output is nominally 6.5 MHz. On a simple counter with a 1 s gate, one count represents about 1 Hz at that output, or 4 Hz referred to the 26 MHz crystal. That is about 0.154 ppm. With a 0.2 s gate, the equivalent resolution step is about 0.77 ppm. A short gate can reveal a brief change at the cost of count resolution. A reciprocal counter can be useful when available. Keep the start and end of the measurement window with each frequency result and capture lock transitions separately.

Account for thermal lag before assigning the issue to an exact temperature. A sensor with a first-order time constant of 10 s would lag a stable 1.2 °C per minute ramp by about 0.20 °C in the simplified model. This illustrates the scale of the effect. Record sensor placement, compare rising and falling sweeps and hold near the affected interval for a repeat. If the issue occurs only during a fast ramp, also record airflow, mounting and supply conditions. Compare several temperatures at the same drive first, then vary drive within the permitted range at a fixed temperature to see how the behavior depends on each variable.

Ask the supplier for data that can settle a release question

Retain one crystal that reproduces the symptom and control units from the same lot. Share the exact ordering code, lot, board revision, load network, drive setting, supply and unfiltered board logs. Agree on the temperature span, measurement location, ramp rates, sample interval, drive power, fixture loading and number of units. Ask for individual frequency and equivalent-resistance traces and the position and width of each excursion. Procurement can list the overall frequency limit, local frequency or resistance criterion and retest rule as distinct requirements. IEC 60444-7 covers activity and frequency dip measurements over temperature. Use the applicable agreed method and conditions in the order record.

If the individual crystal shows a resistance rise and frequency shift near the board event, compare a control lot or another approved drive setting before changing the design. If the individual parts pass the agreed method while the board continues to unlock, investigate the power, loading, mechanical stress and clock path. Verify cold start, oscillator margin, frequency and system recovery again after changing the damping resistor or drive setting. This gives purchasing a clear unit test and gives engineering separate evidence for a board release.

Sources include Microchip AN588, Murata’s frequency-versus-temperature FAQ and IEC 60444-7. For a unit-level test at a specified temperature, see MERLIN’s spurious resonance acceptance window example.