Review the channel plan before ordering an Epson 40 MHz crystal for the CC1175

One person orders a 32 MHz crystal from the TI CC1175 typical application diagram. Another finds a 40 MHz crystal in Epson’s matching guide. Both can point to a manufacturer document. A problem arises if the reference change reaches purchasing and the channel plan and synthesizer settings are still from the earlier revision. Some operating channels can also lie close to an integer multiple of the crystal. Put the crystal frequency, channel plan, register settings, and RF verification in the same change record. Purchasing can then see which quotes are for approved options and which change needs more verification.

What the two manufacturer documents describe

Section 4.12 of the TI CC1175 data sheet lists a crystal frequency range of 32 to 44 MHz, a 10 pF load capacitance, and a 60 Ω ESR value simulated across operating conditions. The typical application illustrates a 32 MHz crystal. Epson groups the CC1125 and CC1175 in its matching guide and lists two 40 MHz, 10 pF options, the FA-128 Q22FA12800101 and FA-20H Q24FA20H00214. It also gives 32 MHz, 10 pF examples in those families. The asterisks mark the packaging suffix. Ask the supplier to fill in the actual orderable part number. Epson’s table is sample-based design guidance. The product team still needs to account for component variation and stray capacitance on its own board.

Both 40 MHz crystals have the same specified load. Obtain the approved package drawing, PCB land pattern, and reference clock configuration. Ask the supplier for the ESR limit, initial tolerance, and rated drive for the exact part. Review the two packages against their own drawings. A 10 pF load specifies the crystal’s effective load. For an illustrative symmetric circuit with 2 pF of estimated stray capacitance, two external 16 pF capacitors give 8 pF in series and 10 pF including the parasitic term. Use this as a starting point. After a layout or package change, verify actual load and startup on the board and link the approved crystal to the revisions of both external capacitors.

What happens if the register image stays the same

The TI family user guide shows that with the frequency word and synthesizer divider held constant, synthesized RF frequency scales with the crystal reference. Suppose a configuration for a 32 MHz crystal targets 920 MHz. Replacing the reference with 40 MHz without changing the programming gives a nominal calculation of 920 × 40 ÷ 32 = 1,150 MHz. This illustrates why the register settings must be regenerated. It is outside the original selected band of 820 to 960 MHz and does not predict a real transmission at that frequency. TI also lists RF programming resolution in this band of about 30.5 Hz with a 32 MHz crystal and 38.1 Hz with a 40 MHz crystal. The reference affects fine corrections as well.

Keep the full register export, the read-back revision identification, channel lists for all sales regions, and measured carriers in the change record. At first article, choose a convenient channel, confirm the crystal and configuration, and verify the actual carrier on the appropriate test connection. Then run the remaining channel and temperature combinations. If a pilot was fitted with a new crystal and offsets were adjusted in old firmware, identify the exact pilot revision in the test record. When a different 10 pF crystal or capacitor is proposed later, the team can reproduce the original hardware and firmware pairing.

If a lab measures the 920 MHz carrier 9,200 Hz high, that is +10 ppm. With correct programming and calibration and proportional scaling from the reference, it corresponds to a 400 Hz increase at 40 MHz. Treat this as a diagnostic expectation. Ask engineering to measure the reference independently. If both offsets agree in direction and scale, check the crystal, load, and correction. If they disagree, compare the register image, channel mapping, measurement timebase, and instrument calibration. Keep carrier offset and spur amplitude in distinct fields with their respective units and limits so production can classify failures from the report.

Measure RF spurs near integer multiples of the crystal

TI notes that spurious emissions in transmit can increase as the channel approaches a multiple of the reference and recommends evaluation within 1 MHz. In the 920 MHz example, 23 × 40 MHz is exactly 920 MHz, an offset of zero. With the 32 MHz reference, the closest multiple is 29 × 32 MHz = 928 MHz, an offset of 8 MHz. After fitting a 40 MHz crystal, put that channel near the top of the spur retest list. Have the RF team measure with the actual transmit power, board layout, and test procedure. The integer-multiple calculation identifies a candidate for testing. Compliance comes from the measured result at the applicable limit. If a regional channel falls right on the 1 MHz boundary, include it as project margin warrants and retain units and precision in the spreadsheet.

Once the configured design is approved, put 40 MHz, 10 pF, the full part number, package drawing, board revision, and configuration revision in the RFQ attachment. Incoming inspection can verify the part number, frequency, load, and any documented ESR requirement. Keep an unconfirmed ESR limit open with the supplier. The RF team then uses programmed first articles to test the carrier and spurs on the channel plan. For separate 32 MHz and 40 MHz builds, link each material and programming record to its corresponding work order. If a board oscillates but misses a channel, check the part and configuration pairing before attributing the error to the crystal lot.