Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Why can an AC-coupled HCSL clock lose most of its swing at the receiver?

A board works with a low-power 100 MHz differential oscillator. A conventional replacement is also marked HCSL. The receiver provides common-mode bias and both lines have series coupling capacitors. After the swap, a frequency counter sometimes reads the clock, but the scope shows much less swing. Redraw the circuit with the capacitors open for DC. On some conventional current-mode HCSL drivers, the capacitors cut off the DC return the driver needs. Identify the output architecture and check the DC operating point on each side.

Termination can also carry the driver's DC current

Renesas AN-808 describes a conventional open-emitter HCSL output with about 50 Ω from each line to ground in the standard network. These resistors serve the line and give the driver's current a defined return. The note illustrates both on-board point-to-point and board-to-board arrangements that maintain a conducting path between the source and its DC termination. Adding series capacitors while leaving both pull-downs on the receiver side blocks that original path.

Some low-power outputs described by Renesas use a different driver and termination. The vendor shows that suitable source-series termination can work without the conventional external pull-down pair. Renesas support also notes that certain low-power outputs lend themselves to AC coupling. A board that supports one low-power part does not establish compatibility with every part labeled HCSL. Get both full ordering codes and the manufacturer circuits. Check whether source impedance or termination is already built in.

At the receiver, internal or external bias determines the average DC voltage after the coupling capacitors. A resistor across the pair sets differential load and gives no absolute DC reference to the two pins. If each line connects to a bias node through a network, check allowable current and the bias rise at startup. Measure common-mode voltage and differential swing separately to distinguish absent drive from a receiver outside its input range.

Draw one DC circuit on each side of the capacitors

Suppose a board has a conventional HCSL source, two coupling capacitors, and receiver bias and differential termination, with no defined pull-downs at the source. Draw the capacitors open and trace the driver's DC path to ground. If the capacitors block it and there is no other path, the design lacks the return specified in the data sheet. In a separate receiver-side drawing, use its data sheet to identify bias and termination and confirm that proper common-mode voltage is established after power-up. Record both findings.

Use the new driver's recommended circuit to choose capacitor and termination positions. If the source needs pull-downs, put the specified DC return before the capacitors. Values and positions come from the parts and link in use. Verify characteristic impedance, termination location, and series damping across the full path. If a receiver with internal differential termination also has another resistor fitted across the pair, the parallel load may still reduce swing after the DC path has been corrected.

Compare by restoring the recommended source-side DC network on the same board and leaving the receiver side unchanged. With suitable high-impedance probes, measure average voltage and AC swing on both lines before and after the capacitors. Calculate differential and common-mode quantities consistently. A scope's 50 Ω input directly connected at the source can temporarily supply a pull-down. A clock that recovers only when the instrument is attached can look like a bad joint. Record probe and input settings, and measure in the load condition specified for the actual parts. Verify differential amplitude, levels, and overshoot where specified, in addition to the measured frequency.

Record both sides before production approval

Give the schematic change and the parts substitution matching revision records. One part may pass with DC coupling and another with capacitors and a particular source-side return. An interchangeable footprint and switching output establish only part of compatibility. Give purchasing and production an interface drawing showing output type, resistor and capacitor locations, receiver bias, and the waveform checks at each end. If a customer changes the receiver or asks for a connection between boards, the two operating points to revisit are already identified.

For systems with several input sources, state which resistor positions must be fitted or left unpopulated for each option. Review shield, connector, impedance, and differential layout. Capture both steady operation and startup, so slow receiver bias settling is visible. Approve the assembly only when the receiver gets a valid clock with the agreed load and startup sequence.

If the vendor provides only a module connector drawing, look for explicit information on internal termination and coupling. Ask for the missing side rather than inferring it from the visible resistors. Label the two hookup variants on the test boards before connecting instruments if alternate oscillators require different circuits.