Jauch JO32 or JRO32 at 32.768 kHz: which oscillator fits the battery-backed clock?

Two Jauch quotes both say 3.2 × 2.5 mm, 32.768 kHz and 3.3 V. Some old boards use the JO32, and a colleague proposes the JRO32. First establish whether the clock must continue driving the timekeeping IC on backup power or can be disabled. Continuous operation requires a loaded current budget. If pin 1 can go low, check whether oscillation stops internally, how long the output takes to return, and what happens if pin 1 floats. Combining both models under one part number can leave a board that measures the right frequency on a bench yet loses time over a weekend outage or misses its first clock edges after enable.

Compare current at the same load and establish whether the clock can stop

Jauch's JO32 32.768 kHz data sheet specifies an AT-cut crystal. Its Table 2 gives 33.5 µA maximum operating current at 3.3 V and 15 pF load. The JRO32 has an internal tuning fork. Its general table gives 1.5 µA at 3.3 V without load, while a separate 15 pF table lists 5.5 µA. The latter gives a more comparable load condition, but the JRO32 column does not say it is a maximum. Keep the JO32 upper bound separate from the JRO32 table-based estimate. Confirm what can be guaranteed for the exact order and measure current on the actual board.

Suppose the source must output continuously for one year. At 8,760 hours, 33.5 µA corresponds to about 293.46 mAh and 5.5 µA to about 48.18 mAh. Those figures are oscillator-only, use a maximum and a tabulated value respectively, and their difference is not a guaranteed battery saving. Account separately for the controller or RTC, isolation, conversion and leakage. If the plan is to disable the output periodically while using the same oscillator as the sole timekeeping source, verify that the external counter still receives a clock during the disabled interval. Even if the oscillator continues internally, the external counter can stop for the entire interval.

Both documents show a high-impedance output when disabled, but the internal states differ. The JO32 stops oscillating and specifies a 5 µA maximum standby current for T1, from −40 to +85 °C. The JRO32 keeps the internal oscillator active, disables the output driver and lists a 1 µA maximum standby current. A high-impedance output therefore does not reveal the internal mode. Check whether another power domain biases the output on the old board. Measure the supply current and receiver counts during operation, disable and recovery so leakage or pull-ups are not charged to the oscillator alone.

Calculate frequency error against each data sheet's reference

For the same −40 to +85 °C range, the JO32 Table 1 combination G and T1 is ±30 ppm. Its stability footnote includes room-temperature tolerance, operating temperature, supply, shock and vibration, and first-year aging. The JRO32 specifies initial tolerance at +25 °C as +5 ±20 ppm and separately gives temperature variation of −140 to +10 ppm relative to the unit's room-temperature frequency. Without room-temperature calibration, a first-order sum is about −155 to +35 ppm, before considering other project factors. After room-temperature calibration, the −140 ppm temperature limit still belongs in the budget.

Imagine a seven-day network outage with 20 seconds of allowable event-time error allocated to the oscillator. At 604,800 seconds, 30 ppm corresponds to 18.14 seconds. For the JRO32, the combined −155 ppm would put the clock about 93.74 seconds behind if the worst-case offset persisted for all seven days. Real temperatures change, so use their recorded history and integrate the corresponding offset. This example compares component limits to the allocation. The 18.14 seconds is not a system guarantee before startup, reference-setting and software counting errors are accounted for.

Check pin 1 and timing before trying the part on a legacy board

With pin 1 left open, the JO32 data sheet says the output is active, while the JRO32 state is undefined. The high-level thresholds also differ. At 3.3 V, 0.7 times supply is about 2.31 V and 0.8 times supply is about 2.64 V. A controller guaranteed to drive 2.5 V high meets the JO32 threshold but gives no such guarantee for the JRO32. Also compare enable delays. The JO32 lists 5 ms maximum. The JRO32 lists 0.5 s maximum to enable and a separate 1 s maximum to start from power-up. If the product checks its first counts only 20 ms after enable, align the timing reference points before judging either part.

If firmware takes one reading 20 ms after enable, an uninterrupted ideal clock would yield about 655 cycles. With the JO32 taking its full 5 ms enable interval, about 15 ms remains, or roughly 492 cycles. The JRO32 worst-case wait can cover the entire 20 ms, leaving no valid cycles in that window. These estimates count stable full cycles. The actual count also depends on starting phase and receiver detection. Record time from enable to a stable clock at the receiver separately from the count over a fixed interval after stabilization. The two captures qualify startup and frequency independently.

Use the data sheet combinations JO32 G, T1, 1V3 and JRO32 TF, T1, V to request complete order identifications. Ask for the applicable data sheet revision, operating temperature range, loaded current conditions and pin 1 state. During trials keep the receiver, 3.3 V supply and observation points the same while exercising external enable, full power-up and long backup operation separately. Compare the land drawings, mounting height and marking documentation as well. For continuous timekeeping, confirm in the first assembly record that backup switchover preserves counting. A new room-temperature frequency check alone cannot qualify the timekeeping and battery budget.