The receiver already has a 100 Ω resistor across the pair, and the nominal differential impedance matches. Measurements still show both clock lines moving up and down together. The manufacturer's alternate circuit uses two 50 Ω resistors in place of the single 100 Ω resistor and connects a capacitor from their midpoint to ground. That capacitor gives the shared motion a path. With ideal symmetry, the two resistors still present the original load to the differential signal. Whether to use the circuit depends on the disturbance frequency, the receiver bias, and the ground connection available for the capacitor.
Differential current goes through the resistors. Common-mode current has a path to ground
When one clock line goes high and the other goes low, differential current enters the two series resistors from one line and returns on the other. Two 50 Ω resistors still present about 100 Ω. If both sides move by equal and opposite amounts around their mean and the resistors are equal, the midpoint stays near that mean. The differential transition then causes very little charging or discharging of the capacitor. TI's SLAA840 figures 1 and 2 compare plain across-the-pair termination with split termination and show the symmetrical receiver connection and midpoint capacitor.
When both lines rise together, the shared change produces practically no voltage across a single resistor connected between them. In the split circuit, each line can send current through one resistor into the midpoint capacitor. At frequencies where the connection to ground has low impedance, the network gives common-mode current a short route at the receiver. A capacitor blocks steady DC, so a persistent ground offset between boards still has to be handled within the DC operating conditions. Shorting the midpoint directly to ground would apply a different DC load to each differential output pin.
This assumes compatible DC-coupled driver and receiver levels. If the clock lines already have series coupling capacitors, establish the input DC bias using an arrangement the receiver supports. A capacitor from the termination midpoint to ground cannot set the average voltage after the series coupling capacitors. When the manufacturer's circuit connects the midpoint to a bias reference, confirm the bias, bypass, and load limits for that exact part. Check whether on-chip termination is already enabled before deciding whether to remove or disable the original across-the-pair resistor.
Estimate where the capacitor starts to matter
Assume a symmetrical receiver network with two 50 Ω resistors and a 100 nF midpoint capacitor. For pure common-mode drive, the lines move together and the two 50 Ω branches act in parallel, giving 25 Ω. Multiplying by 100 nF gives a time constant of 2.5 µs and an ideal corner of about 63.7 kHz. At 1 MHz an ideal 100 nF capacitor has a reactance of about 1.59 Ω, low alongside the model's 25 Ω. This estimates the behavior of the termination branch and helps choose a band to test. Actual noise reduction also depends on the source of the noise, common-mode line impedance, ground inductance, and component parasitics.
The differential branch still has two 50 Ω resistors in series. If the receiver's internal 100 Ω is already enabled, adding the external pair places two 100 Ω loads in parallel, for a combined 50 Ω. Driver swing can change, so the original prototype waveform no longer establishes acceptance. For boards with different assembly options, read the on-chip configuration and check each population separately. Confirm the capacitor's effective capacitance at its actual bias and its self-resonant frequency. The part and mounting layout need to carry the disturbance current at the frequencies of interest.
Keep the source, cable, and receiver the same for an A/B test. Compare a single across-the-pair resistor with two matched, symmetrically mounted resistors and the midpoint capacitor. Record differential voltage at the receiver and the average of the two lines. Check that the edges still cross the required thresholds cleanly. Run the supply or interface that can create the disturbance and inspect the problem band. Keep probe channel delay and bandwidth fixed, because mismatch between measurement channels can appear as noise in the average trace. A measured drop in common-mode noise supports the change if differential swing and high and low pulse widths still meet their limits. If the edge deteriorates, examine resistor matching, pad geometry, and the ground return before changing capacitance.
The component locations are part of the circuit
Put the two resistors next to the receiver pins and keep stubs off the main pair short. Make the midpoint capacitor's ground path short, and check that the selected reference can carry the high-frequency return current. If the network is near the connector and the trace continues to a receiver, identify where the line actually ends and review the intervening branches. Asymmetry in resistors or pads can still convert common-mode disturbance into differential error. The parallel-resistance calculation alone cannot establish how the finished board behaves.
For review, draw one small diagram of the actual differential load and another showing the common-mode return through the capacitor. Write down what acceptance is meant to demonstrate, such as receiver common-mode voltage while a particular peripheral operates in the enclosure, along with clock swing and minimum pulse widths. If the plain termination already meets these conditions, keeping it also preserves a straightforward comparison with the manufacturer's circuit. Use split termination where a measurable common-mode disturbance calls for it and the bias, return path, and differential signal all remain suitable.
Record disturbances for each supported speed. A low-frequency clock can still have fast edges. Choose the filter band from the measured common-mode disturbance. Keep a source-side measurement as a control so a change at the oscillator is not credited to the midpoint capacitor.
