A compact logger uses a low-frequency active oscillator soldered directly to its board. The assembly includes underfill for mechanical reasons. A second production site builds the same board and part number using a different material and cure profile. The finished clock still counts correctly at room temperature. The decision is whether that new process is covered by the equipment's qualification.
Board-level underfill is material between the component and the board. It differs from an adhesive or optical barrier applied to the top. Page 1 of the SiTime SiT1581 Rev 2.01 datasheet lists board-level underfill among the conditions covered by its all-inclusive stability specification. It separately gives initial tolerance after two reflows at 25 °C. The SiT1534 manufacturing guidance explicitly accepts board-level underfill. Confirm which product and process the evidence addresses. That wording does not qualify every material, cure profile, and board construction for the equipment.
Record where the reading changes
Use a control group with the qualified process, a group with the proposed material or cure, and an unfilled engineering group if needed. Control the oscillator lot, board revision, and placement process. Record frequency after reflow, before filling, after cure and return to the defined measurement environment, and after the required stress tests. Use comparable supply, loading, instrumentation, and temperature. Follow the same serial number across the steps. A release plan still needs agreed sample sizes, limits, and records.
Assume a 32.768 kHz unit reads 32,768.20 Hz after reflow and 32,767.85 Hz after curing and returning to the same temperature. The process shift is −0.35 Hz or about −10.68 ppm. The final absolute difference is −0.15 Hz or about −4.58 ppm. The small final error does not imply a small process change. These are worked values. In a real comparison, an uncontrolled reading could also include the effect of heating, test loading, or drift.
Compare the change and spread in the new group with those in the qualified group. Without a control, neither the cause nor the relevance of a shift is clear. Take readings at agreed points after temperature or humidity stress and return to a comparable measurement condition. If opening the enclosure changes strain or airflow, use a documented observation method or a separate controlled comparison.
Include the enclosure step
A bare board may still be in the panel and may not yet experience mounting screws, wiring, or the product's heat path. Epson's handling guidance warns of solder and package damage caused by board bending for the specified packages. That warning does not establish a failure mechanism for a different MEMS product. It does identify a reason to validate the installed equipment and distinguish installation stress from the effect of the cure.
When enclosure assembly shifts frequency, check what happens afterward under a controlled unload. Reversible shifts, persistent shifts, and power interruption call for different dispositions.
If the change is driven by material availability, retain material identity, lot, storage and thaw conditions, amount, and cure profile. Two materials described as epoxy may differ in shrinkage, viscosity, and reliability. Ask the material and oscillator suppliers about the exact proposed condition. Visual checks and power-up support only those parts of the qualification.
The purchasing request can identify the board process and the equipment requirement that relies on the clock. The engineering file can then put the actual configuration, assembly stages, and original readings on one traceable record. This lets the next change reviewer determine which evidence still applies and which tests need to be repeated.