Why a 40 MHz NDK NX3225SA crystal needs an STD-CQR-1 or STD-CQS-1 receiving record

Two reels say NX3225SA on the packaging, and the devices indicate 40 MHz. Before combining the lots, check the two NDK specification numbers. The standard and automotive standard NX3225SA documents cover 40 MHz and share nominal dimensions, room-temperature initial tolerance, and load capacitance. An inspection limited to frequency, outline, or appearance can miss the distinction. If the product needs high-temperature performance or has a limited oscillator startup budget, select the specification on the order and compare receiving evidence against it.

Identify the performance specification for the requested frequency

The standard part is STD-CQR-1. At 40 MHz, NDK lists a maximum equivalent series resistance of 50 Ω and temperature variation of ±25 ppm relative to 25 °C across −40 to +85 °C. The automotive standard part is STD-CQS-1. At 40 MHz, its resistance limit is 100 Ω and its relative temperature variation is ±50 ppm across −40 to +125 °C. Both specify an 8 pF load, ±15 ppm initial tolerance at 25 °C, and a 10 µW drive with 200 µW maximum. NDK asks for model, frequency, and specification number when quoting or ordering. Include all three and obtain the actual order identity, controlled revision, and packaging from the supplier.

The automotive document illustrates body marking. It identifies frequency, trace, month, last digit of year, and manufacturer mark. The illustration does not establish a way to authenticate STD-CQS-1 from the top mark alone. Optical character recognition can help screen for 40 MHz. Check the reel label, accompanying documents, and supplier cross-reference for the specification number. Keep the original reel identity and lot on split reels. For loose samples, establish their source and controlled specification before qualifying them for the production position. A room-temperature frequency reading cannot supply missing identification.

The thermal and startup budgets can lead to different choices

At 40 MHz, 1 ppm is 40 Hz. A same-direction sum of initial tolerance and temperature variation is 15 + 25 = 40 ppm for CQR or 1,600 Hz, and 15 + 50 = 65 ppm for CQS or 2,600 Hz. The system may allocate additional error to assembly, load mismatch, and aging. The CQR calculation applies only within that specification’s temperature range. Establish the actual required range and maximum allowed deviation for the board before deciding which documents and parts qualify.

For startup, use actual board data. Suppose the oscillator circuit measures 280 Ω of negative resistance under the applicable conditions, the internal criterion is a ratio of five, and the comparison has been put on a consistent impedance basis. Dividing by 50 Ω gives 5.6, while dividing by 100 Ω gives 2.8. The former meets the illustrative limit and the latter calls for design review. If the method uses effective resistance under load, perform the applicable conversion rather than treating a series measurement as that resistance. An automotive sample measuring below 50 Ω at room temperature only establishes the tested value. Use the 100 Ω guarantee for volume unless a tighter grade is approved.

Link materials and board tests to the specification number

Suppose one terminal product stays below 70 °C and a second version has a verified crystal location of 118 °C. The indoor version can consider CQR under its own electrical and commercial criteria. For the hotter version, confirm the CQS approval and startup on the actual board. If a ratio of 2.8 fails the startup requirement, engineering can change the board or gain, or purchasing can ask about a documented tighter resistance limit at the required frequency. A handful of low-resistance room-temperature samples cannot establish the performance of a reel. Keep component compliance separate from the board startup result in the approval record.

During first article, both candidates can use boards made from the same batch, with distinct test identifiers. Suppose ten boards are divided into two groups of five and each board undergoes room-temperature and cold startup. If one automotive unit fails to produce a clock twice in ten cold starts, retain the timestamps for all ten attempts, mark the two failures, and keep the crystal identifier. The other eight startup times cannot replace those failures with an average. For a resistance retest, agree on the method in the documents and measure unsoldered specimens under matching conditions. Keep the pilot on hold while engineering investigates. In the RFQ, have the supplier report sample quantity and test conditions for each specification so a wider-temperature pilot cannot mistakenly qualify another electrical version.

Purchasing specifies NX3225SA, 40 MHz, and the agreed specification number. Receiving links the lot to its reel label or documented manufacturer cross-reference. Engineering uses the same specification number on first-article records with the board, actual capacitors, startup temperature, and observations. If one quote offers two specification numbers, have the supplier report them as separate line items. A shipment documented only as NX3225SA with room-temperature operation still needs evidence of the applicable specification before assignment to a work order with defined temperature and resistance limits.