A 10 MHz OCXO shifts 0.02 Hz at low pressure. How does it enter the stability budget?

The same 10 MHz oven-controlled crystal oscillator passes at an ordinary-pressure station but shows a small frequency offset at a lower-pressure site after warming up. The equipment log shows little change in ambient temperature, and an engineer wants to derive a pressure coefficient from the two site readings. Those readings also include transport, remounting, a new power-up and different humidity. Before putting the difference in a purchasing frequency budget, run a repeatable pressure sequence in one fixture and see which measurement tracks the offset.

Define the pressure and frequency quantity used for acceptance

Control absolute pressure at the oscillator. An environmental monitoring system may report pressure corrected to sea level, which would describe the wrong test condition. Send suppliers the minimum and maximum absolute pressure where the equipment operates and state whether it must run through the transition. If the enclosure has controlled internal pressure, use the environment the oscillator actually sees. A hermetic seal describes construction. Even without gas exchange through the cavity wall, external pressure can change heat transfer. Board or assembly measurements should establish the size of the effect.

Walls and Gagnepain’s paper on quartz oscillator environmental sensitivities discusses how pressure and humidity can change conduction, convection and internal thermal gradients. The same ambient temperature can coexist with different case temperatures, internal gradients or oven power, so record those quantities where accessible. Walls’s tests on four 5 MHz quartz oscillators also found improved longer-term stability in some units when pressure and humidity were controlled. Supplemental tests led the author to identify humidity as the likely larger contribution. If field frequency and weather move together, test humidity and pressure separately. That study does not provide a quantitative pressure coefficient for an arbitrary 10 MHz part.

Use the return to normal pressure to estimate baseline drift

These readings are illustrative. Keep mounting orientation, cables, supply and output load fixed. Record the settled offset y at 101 kPa absolute, then 81 kPa, then 101 kPa again. Express y in ppb relative to nominal 10 MHz. Assume equally spaced window midpoints, first nominal-pressure offset set to zero, low-pressure value −2.0 ppb and return value +0.4 ppb. If baseline drift is approximately linear, the nominal-pressure baseline at the middle window is about +0.2 ppb. Subtract it for a low-pressure shift of −2.2 ppb. Divide by −20 kPa to get a local slope of about +0.11 ppb/kPa, or +11 ppb/bar. At 10 MHz, −2.2 ppb is −0.022 Hz.

If the specification covers frequency change between two operating pressures, record the range observed under those plateau conditions. For a compensation coefficient, repeat the pressure cycles and verify approximate linearity at intermediate pressures. Where window midpoints are unevenly spaced, interpolate the baseline using actual times. If the return residual materially exceeds drift measured at constant pressure, report it and the settling time. It may represent hysteresis, slow thermal equilibrium or another effect. Forcing every return reading to zero would hide that information.

The coefficient also depends on the accuracy of both differences. For this example, assume the standard uncertainty of the baseline-corrected frequency difference is 0.2 ppb and that of the pressure difference is 0.5 kPa. If the contributions are approximately independent, first-order propagation for the ratio gives √[(0.2/20)² + (2.2 × 0.5/20²)²] ≈ 0.010 ppb/kPa standard uncertainty. List return hysteresis and lot-to-lot differences separately if they are outside this estimate. A guaranteed limit across lots requires evidence beyond one fitted test unit.

Record three time series together

Pressure and humidity
Use suitable environmental equipment to record measured absolute pressure, pressure ramp rate, plateau duration, gas conditions and humidity. With dry test gas, state how and where dew point was measured. Run a pressure change with humidity as constant as practical, then a separate humidity comparison as required by the application. Identify steady-state windows after pressure and temperature both meet the defined conditions. If the application limits peak frequency error during pressure changes, retain continuous data during the transition.
Temperature and supply
Record chamber air temperature, local case or board temperature and supply current at the device. Reproduce the installed bracket or thermal interface if present. A change in steady-state oven current calls for checking the thermal environment. A small controlled temperature change at fixed pressure gives a bench temperature response for comparison. If the pressure cycle produces a temperature transient of similar sign and timing, one run cannot isolate a separate pressure coefficient.
Frequency and reference
Use an independent reference with stability comfortably below the expected fractional frequency shift, outside the pressure-changing region. Record comparison method, reference, sampling times and fixture. Cable strain or connector changes can matter at millihertz levels. Before installing the sample, check the reference chain for repeatable feedthrough phase changes as the chamber state changes. Keep the plateau statistics and uncertainty and the raw time trace for review.

When procuring a pressure grade, ask the supplier whether it means the oscillator passes after storage, continues to output during pressure changes or meets frequency limits after a stated dwell. These conditions apply to different periods of the test. Suppose a system allocates only 1 ppb to pressure over 20 kPa. Under a linear approximation, the coefficient budget is 1/20 = 0.05 ppb/kPa. The illustrative 0.11 ppb/kPa exceeds it. The team can evaluate restricting the pressure range, changing the installed thermal path or selecting a complete order code with measured results. Repeat the sequence at the same reference condition to establish the actual new margin.

In the incoming qualification file, keep the purchase pressure range, photographs or geometry of the setup, pressure, temperature and humidity history, the permitted frequency error at each stage, recovery results and uncertainty. A bench pass alone still calls for checking whether the test reached the low-pressure end. For completed measurement equipment, include the actual mounting bracket and thermal interface in the sample qualification. When replacing the OCXO, enclosure or heat path, the team can repeat the same pressure profile and reassess the decision.